ASAHI YUKIZAI Dymatrix AVNVM User Manual Download Page 16

取扱説明書

 

User’s  Manual 

AVNVM                                                                                                                                                                                                                                                                                       

15

 

 

How to connect a tube to a fitting         

 

Flowell 20 series

 

1)

  Cut a tube at right angle. Pass the nut through the tube. 

2)

  Using the dedicated tool, force the ring to fit into the inner surface of the tube. 

3)

  Insert the tube provided with the ring into the main body by hand. Form the tube end straight 

beforehand. 

4)

  Place the nut and turn it by hand until it will not go any further. Then use a spanner to tighten the nut by   

giving a 1/2 turn. 

 

Flowell 60 series

 

1)

  Cut a tube at right angle. Pass the nut through the tube. 

2)

  Using the dedicated tool, flare the tube.   

3)

  Insert the tube into the fitting. Turn nut up to the required clearance by spanner, after tightening by   

hand firmly. 

4)

  To check the tightness of union nut, use the dedicated gap gauges. 

 

Super Type Pillar Fitting

 

1)

  Cut a tube at right angle. Pass the union nut through the tube. 

2)

  Using the dedicated tool, force the sleeve to fit into the inner surface of the tube. 

3)

  Insert the tube provided with the ring into the main body by hand. Turn nut up to the required clearance 

by spanner, after tightening by hand firmly. 

4)

  To check the tightness of union nut, use the dedicated gap gauges. 

 

Super 300 Type Pillar Fitting

 

1)

  Cut a tube at right angle. Pass the union nut through the tube. 

2)

  Using the dedicated tool, force the sleeve to fit into the inner surface of the tube. 

3)

  Assemble the sleeve to the fitting and then tighten the fitting until the union nut makes contact with 

the projection on the gauge ring and a click can be heard. 

 

Flare Type

 

1)

  Cut a tube at right angle. Pass the nut through the tube. 

2)

  Using the dedicated tool, flare the tube. 

3)

  Insert the tube into the fitting. Turn nut up to the required clearance by spanner, after tightening by hand   

firmly. 

4)

  To check the tightness of union nut, use the dedicated gap gauges 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

For further information, see the instruction manuals issued by relevant fitting manufactures. 

 

Do not overtighten the nuts. (That may damage the fittings and nuts.) 

 

Make sure the flow direction of the valve is correct. 

 

Caution

 

Summary of Contents for Dymatrix AVNVM

Page 1: ...o DTS111 07 1 General cautions 5 Part names 6 Specifications 7 How to select types 9 Dimension 11 How to operate 12 Technical data 13 Method of installation 14 Method of piping 16 Check items 17 Cause...

Page 2: ...User s Manual AVNVM 1 General cautions 1 2 AV V 029 EJ N2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2...

Page 3: ...User s Manual AVNVM 2 1 1 AV V 029 EJ N2 2 3 4 5 6 1 2 3 4...

Page 4: ...lve unable to seal 4 Please contact us when use for the fluid containing the crystalline substance It would make the valve unable to seal 5 Use the products within the range of working pressure shown...

Page 5: ...ding on the working condition If cavitations are observed review the fluid pressure and piping design 3 Do not use the valve in negative pressure It can be damaged 4 Handle the products carefully to p...

Page 6: ...User s Manual AVNVM 5 Parts names Body Diaphragm Actuator O O ring Metal parts Parts Chemical resistant Wetted parts 0 1 PFA PTFE SUS304 SUS304 PTFEcoating PTFE PVDF FKM EPDM Viflon F Kalrez 6190...

Page 7: ...0 25 Items Unit 35 Ambient Temperature 5 60 Flowell 20 series Flowell 60 series Super Type Pillar Fitting Super 300 Type Pillar Fitting Flare Type Tube Rc Actuation Medium Temperature Proof Pressure W...

Page 8: ...x 9 53 M I S Ordering code example AVNVM30 010 PT3I1SV006 P P Body Materials 1 2 6 Actuator Size 1 30 35 35 30 AVNVM S Connection 1 PFA PTFE 06 10 12 6 x 4 10 x 8 12 x 10 mL min mL min mL min L min Co...

Page 9: ...9L min 10L min 0 500 1000 1500 2000 2500 3000 3500 4000 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Flow rate mL min Handle rotations 3800mL min 3000mL min 1800mL min 0 200 400 600 800 1000 1200 1400 0...

Page 10: ...109 Super Type Pillar Fitting inch mm 69 88 95 Super 300 Type Pillar Fitting inch mm 68 85 93 Flare Type inch 86 97 101 Tube inch mm 90 95 95 30 Max 104 5 21 5 5 6 4 10 8 12 10 6 35 4 35 9 53 6 35 12...

Page 11: ...itting Flowell 20 series Flowell 60 series Flare Type Super Type Pillar fitting Super 300 Type Pillar fitting inch 6 35 4 35 9 53 6 35 12 70 9 53 6 35 3 95 9 53 6 33 12 7 9 5 Tube diameter mm 6 4 10 8...

Page 12: ...l the desired flow rate is achieved Handle More flow Less flow Unlock state Lock state 0 6N m Be sure to operate the handle with hands Please operate a handle within 0 6N m torque Clamping them with a...

Page 13: ...User s Manual AVNVM 12 Fluid Water ambient The data shown here is the experimental values and the reference values Technical date Handle rotations Flow rate...

Page 14: ...ee Dimension Flow direction The flow direction of this product is specified For the details see the separately attached specifications Always flow medium in a specified direction If omitted that may d...

Page 15: ...User s Manual AVNVM 14 Method of piping Flowell 20 series 1 2 Flowell 60 series Super Type Pillar Fitting Super 300 Type Pillar Fitting Flare Type...

Page 16: ...e inner surface of the tube Insert the tube provided with the ring into the main body by hand Turn nut up to the required clearance by spanner after tightening by hand firmly To check the tightness of...

Page 17: ...nge We recommends you to check them at least once a year When finding any problem or trouble call us Check points Check items Valve Appearance flaw crack distortion discoloration Leakage from the valv...

Page 18: ...by actuating The piston or spring is damaged Replace the valve Leakage in the fully closed position The diaphragm is abraded Replace the valve Flaw in the diaphragm or body Foreign matter is caught in...

Page 19: ...of product improvement 2020 12 v07 110 0005 3 24 6 21 TEL 03 5826 8832 FAX 03 3834 7592 For inquiries contact Head Office Overseas Department Tel 81 3 5826 8831 Fax 81 3 3834 7592 21st Floor Ueno Fro...

Reviews: