6.
Error Codes on label printer. UF2000/1 (page) and UF2000/2 (page 40)
See UF Binder for instructions on error correction.
Error 1
Alignment time out of tolerance (Butt fusion Only)
Error 2
Heat Soak Time out of tolerance
Error 3
Adjustment time too long
Error 4
Ramp-up time and/or joining pressure out of tolerance
Error 5
Cooling time too short
Error 6
During cool down period, the joining pressure is out of tolerance
Error 7
Capacity of welding data is exhausted
Error 8
1990 welds complete, unit may need to be returned for routine
maintenance. (Only displayed when cycling tool on/off)
Error 9
2200 welds complete, unit should be returned for routine
maintenance. (Only displayed when cycling tool on/off).
Asahi/America, Inc.
UF 2000/1
Page 7 of 1
8