8
ECOcycle Aurora Ⅱ
Name of Item
Code No.
Explanation of the Item
Limit Scale LS-45 Ⅱ
LS452
Scale to be used to prevent over-filling when recovery
cylinder has no float sensor.
Limit Scale LS-150 Ⅱ
LS152
AR molecular sieve pack
AR222
Replacement molecular sieve for inside of Molecular sieve pack.
Charge faster
WA6625
Use when recovering R134a and R12.
Check Mate
RT700K
Easily calculation PPM for contaminate of oil and
moisture / acid of refrigerant.
Refrigerant Analyzer Ultima HV
NT2004HV Judgment of refrigerant if possible to use for reclaim.
Vacuum Pump
Various
Type
High efficient 2-stage vacuum pump with a check valve.
Cooling unit CL3 (3/8")
ES801
Improves the efficiency of recovery in summer climate,
recovery in a large volume or recovery of R410A by
using together with a recovery machine.
Header
TF013
Recovery of up to 6 units at the same time.
Piercing valve
TF014
Makes a connection port for recovery from a system
which has no service port such as a home use
refrigerator, etc.
1/4" Charging hose with pressure
gauge (for use with cylinder)
Y02002A
Connect to recovery cylinder and check the amount of air
mixed in the refrigerant.
1/4" Hose with vacuum needle
Y02003A
Checks depth of vacuum in the system being recovered to
judge completion of recovery.
Sight Glass
Y41145
Visually check refrigerant flow either in vapor or liquid.
Adapter for different diameter
for auto A/C (quick type) 3/16"
female x 1/4" male
Y19120
Adapter to connect to the small service port (3/16") for
R12.
High pressure quick joint
for R134a (M12)
Y03100A
For quick connection to the service port (high pressure
side) for R134a.
Low pressure quick joint
for R134a (M10)
Y03200A
For quick connection to the service port (low pressure
side) for R134a.
1/4” Ball Valve
Y93843
Prevent release of refrigerant when Disconnecting hose.
Quick charging valve A
Y18975
Can be used without leaking refrigerant.
Recovery speed improves without Schrader.
Charging hose plus Ⅱ with
SealRight fitting
Various
sizes
available
Low loss anti-blow back SealRight fitting traps
refrigerant in the hose when disconnected.
Charging hose plus Ⅱ for R410A
Charging hose for R410A.
Charging hose plus Ⅱ with
ball valve for R410A
Charging hose with ball valve for R410A.
Charging hose plus Ⅱ for R134a
Charging hose for R134a.
COMPONENTS
OF
THE
MACHINE
* Our Limit Scale must be used when recovery
cylinders (without float sensor) are used.
* Our original recovery cylinder should be used.
Description
Capacity
Port
Code No.
Refrigerant
recovery cylinder
(with float sensor)
1L
1/4" flare
TF040
6L
TF090
12L
TF056
24L
TF057
40L
1/4" flare
TF130
3/8" flare
TF131
120L
1/4" flare
TF110
3/8" flare
TF129
1/2" flare
TF097
3/4" flare
TF098
Description
Capacity
Port
Code No.
Refrigerant
recovery cylinder
(without float sensor)
24L
1/4" flare
TF080
120L
TF070
Optional Accessories
(Other Air-Conditioning Equipment)
Optional Accessories
(Recovery Cylinder)
Summary of Contents for ECOcycle Aurora II
Page 26: ...25 ECOcycle Aurora...
Page 27: ...26 ECOcycle Aurora...