background image

FEATURES

 

DIGITAL COMMUNICATION

LIQUID CRYSTAL DISPLAY WITH ROOM & SET TEMPERATURE

BLUE LED ILLUMINATION

INDIVIDUAL LED’s FOR EACH MODE

AUTO / ON FAN

FAHRENHEIT & CELSIUS DISPLAY

ROOF TOP FAN CAN BE USED TO PROVIDE ADDITIONAL AIR CIRCULATION DURING
FURNACE OPERATION

UNIVERSAL DESIGN IS COMPATIBLE WITH COOLING, HEAT PUMPS, HEAT STRIPS, &
FURNACES (Heat Strips cannot be used on Heat Pump models)

OPERATION 

1) Press & Hold

 for 3 seconds to turn ON/OFF the system. 

2) Press the

 to select the desired mode.  Each button press with cycle through the available modes. 

3) Press the

 to select the desired room temperature.  Each button press will change the Set 

Temperature display by one digit. 

4) Press the

 to select the desired fan setting & speed. 

5) After the last button is pressed the Blue Illumination will remain for 15 seconds and then turn off and

enter the sleep mode.  The LCD will still display temperatures & fan settings.

6) To wake up the Thermostat, press any button for one second and release.  You can now make changes to

the settings.

TEMPERATURE FORMAT 

1) Press & hold buttons

 together for 3 seconds to change from °F to °C.  Press and hold these 

buttons again for 3 seconds to change back to °F.  The Room Temperature range is 32°F to 99°F.  The 
Set Temperature range is 60°F to 86°F. 

FAN OPERATION 

1) Press the

 to cycle through the available fan settings and speeds.  Each press will change from Auto, 

On High (3 Fan Icons), On Medium (2 Fan Icons), & On Low (1 Fan Icon). 

2) In the Auto setting, the Fan will cycle On/Off with the compressor or furnace.  The speed of the Fan will

be determined by the temperature difference between Room & Set.  If the temperature is greater than 4
degrees, the speed is High.  If the difference is 3 - 4 degrees, the speed is Medium.  If the difference is 2
degrees the speed is Low.

3) In the On setting, the Fan will run continuously at the selected speed regardless of compressor or furnace

state.

COOLING OPERATION 

In this mode, the compressor will cycle On/Off based on the Room/Set temperature.  The Fan will run first and 
then the compressor will turn on  in approximately 3  minutes.  If the  Fan  is set to Auto, the Fan  will  stop 30 
seconds after the compressor stops. 