22
ARZUM
PROBLEM
1.’Power control plate’ power
doesn’t switch on
2. ‘Power cut
1:Power control plate damaged
2:Fuse damaged
3:Heating plate damaged
1.Heating plate damaged
2. Power control plate damaged
1. Capacity of porridge is
excessive
2. Not install the overflow-proof
lid
Power Control plate had trouble
1.Capacity of rice is much or less
2.The proportion of water and rice
is not suitable
3.Inner pot obliques
4. Something between inner pot
and heating plate
5. Inner pot shape damages
6. power control plate damaged
7. Main temperature control
machine unusual
1.Inner pot shape damages
2. Main power control plate
damaged
3. Main temperature control
machine unusual
4 .Inner pot obliques
1: Check rice cooker if it is
unplugged
2: Wait
Contact Repair Service Centre
Contact Repair Service Centre
1. Adjust the capacity
2. Install the overflow –proof lid
Send to Repair Service Center
Capacity of rice and water should be
adjusted, should be limited between
highest and lowest.
Adjust the proportion of water
and rice
Turn round inner pot, check sensor
of ‘heating plate’
Clean up the sundries
Send to Repair Service Centre or
buy a new one.
Send to Repair Service Centre
Send to Repair Service Centre
Send to Repair Service Centre or
buy a new one.
1.Send to Repair Service Centre
2.Send to Repair Service Centre
3. Turn round inner pot, check
sensor of ‘heating plate’
Indicator unlights
Heating plate unheat
Indicator lights, heating
plate unheat
Porridge Overflow
LED show: E1, E2, E3,E4
Rice undercooked
Rice overcooked
METHODS OF SOLVING
REASON
Problem and Solutions