background image

Multi Q Owner's Manual  v 1.8 CE ©2003 ARX®

Multi Q Owner's Manual   v 1.8 CE ©2003 ARX®

2

7

Multi Q Specifications

Filter Type

Full Parametric State Variable

Maximum Cut/Boost

±18 dB, user variable

Bandwidth

3 octaves to 1/20th octave, user variable Input

Impedance

Balanced   20 Kohms

Unbalanced 10 Kohms

Input Headroom

+ 21 dB

CMRR

>60 dB, 20 Hz - 20 KHz

Output Impedance

Balanced   300 ohms

Unbalanced 150 ohms

Output Level (Max)

+ 21 dB

Frequency Response

10 Hz to 20 KHz, ± 0 .5 dB

Signal to Noise ratio

One Channel:

-98 dB Unweighted

-101 dB ‘A’ weighted

Six Channels:

-88 dB Unweighted

-93 dB ‘A’ weighted

Distortion

.004% THD @ 0 dB,1KHz

Dynamic Range

119 dB (single Channel)

Power Requirements

100-120 V AC, 220-240 V AC 50-60 Hz

8 Watts (8 VA)

Weight

5 lbs/2.2Kg

Dimensions

19"W x 1¾"H x 6"D

482 x 44 x 155mm

 Input Connector type

Balanced Jack (TRS)

 Output Connector type

Balanced Jack (TRS)

This symbol indicates that a Slow Blow fuse is used in this equipment.
Replace with same type and value only

This symbol is intended to alert you to the presence of uninsulated
dangerous voltage within the product's enclosure that may be of sufficient
magnitude to constitute a risk of electric shock.

This symbol is intended to alert you to the presence of important operating
instructions contained in this owner's manual

WARNING SYMBOLS USED ON THIS EQUIPMENT

WARNING SYMBOLS USED ON THIS EQUIPMENT

WARNING SYMBOLS USED ON THIS EQUIPMENT

WARNING SYMBOLS USED ON THIS EQUIPMENT

WARNING SYMBOLS USED ON THIS EQUIPMENT

IMPORT

IMPORT

IMPORT

IMPORT

IMPORTANT 

ANT 

ANT 

ANT 

ANT 

- PLEASE READ THIS FIRST

- PLEASE READ THIS FIRST

- PLEASE READ THIS FIRST

- PLEASE READ THIS FIRST

- PLEASE READ THIS FIRST

This is a dual voltage unit. It is essential that you check that the voltage on the

fuseholder cover below the AC connector on the rear of the chassis is set correctly

before connecting it to AC power.

To change, pull fuseholder out and rotate 180

o

, then push in again. Do not insert power

cable into unit until voltage has been correctly set. Do not plug power cable into AC
power until voltage has been correctly set

THIS IS SET FOR

100 V AC TO 120 V

AC OPERATION

THIS IS SET FOR

220 V AC TO 240 V

AC OPERATION

Complies with 89/336/EEC EMC Directive,

amended by 92/31/EEC and 93/68/EEC; CE 73/

23/EEC Low Voltage directive and meets the

following standards: EN 55013 : 1990, Sections

3.2 and 3.5 EN 55020 : 1988, Sections 4.3, 5.4,

6.2, 7.0, 8.0. Complies with Australian Standard

AS/N25 1053

Reviews: