Mix 8 Specifications
Mode of operation
8:2 Stereo Line Mixer
Input Impedance
Balanced XLR/Jack 44 K Ohms
Unbalanced XLR/Jack
22 K Ohms
Phono (RCA)
10 K Ohms
Input Headroom
+21dB
Output Level
+27dB
Output Signal/Noise
(@ unity gain)
-84dB unweighted
-89dB A weighted
Dynamic Range
111dB
Output Impedance
300 Ohms Balanced
150 Ohms Unbalanced
Frequency Response
20Hz-20 KHz ±0.5dB
Distortion
(@ unity gain)100Hz.004%
1KHz
.0042%
10KHz
.006%
Input Connector Types
Female XLR, Jack, RCA(phono)
Output Connector Type
Male XLR
Headphone Section
Output Level (Max)
2 watts
Minimum Load
8 ohms
Level Control
Pre Master Outputs, Pre Master Faders
Post Channel Faders
Connector Type
Stereo Jack (Tip L, Ring R, Sleeve Gnd
Power Requirements
100/120 V AC 50 - 60 Hz
220/240 V AC 50 - 60 Hz 8 Watts (8 VA)
Size
19”W x 6”D x 1¾”H, 482 x 155 x 44mm
Weight
2.2 Kg (5 lbs)
This symbol indicates that a Slow Blow fuse is used in this equip-
ment. Replace with same type and value only
This symbol is intended to alert you to the presence of uninsulated
dangerous voltage within the product's enclosure that may be of
sufficient magnitude to constitute a risk of electric shock.
This symbol is intended to alert you to the presence of important
operating instructions contained in this owner's manual
WARNING SYMBOLS USED ON THIS EQUIPMENT
IMPORTANT
- PLEASE READ THIS FIRST
This is a dual voltage unit. It is essential that you check that the voltage on
the fuseholder cover below the AC connector on the rear of the chassis is
set correctly before connecting it to AC power.
To change, pull fuseholder out and rotate 180
o
, then push in again. Do not
insert power cable into unit until voltage has been correctly set. Do not plug
power cable into AC power until voltage has been correctly set
THIS IS SET FOR
100 V AC TO 120 V
AC OPERATION
THIS IS SET FOR
220 V AC TO 240 V
AC OPERATION
Complies with 89/336/EEC EMC Directive,
amended by 92/31/EEC and 93/68/EEC and
meets the following standards:EN 55013 :
1990, Sections 3.2 and 3.5 EN 55020 :
1988, Sections 4.3, 5.4, 6.2, 7.0, 8.0.
Complies with Australian Standard AS/N25
1053