ARX LSP-2 Owner'S Manual Download Page 2

LSP-2 Speaker Processor 

 

Owner's Manual   v 2.2 CE ©2000 ARX®

LSP-2 Speaker Processor 

 

Owner's Manual   v 2.2 CE ©2000 ARX®

2

7

LSP 2  Specifications

Input Impedance

20Kohms Electronically balanced

Maximum Input Level

+20dB

Input Level Control

infinity – 0dB (no gain)

CMRR

>50dB @ 1KHz

Output Impedance

(Band 1 & Band 2 output)

300 ohms Balanced
150 ohms Unbalanced

Maximum Output Level

+22dB

Low Output Level Control

infinity – +6dB (gain)

Signal to Noise Ratio

–96dB Band 1 output
–93dB Band 2 output

Frequency Response

20Hz—20KHz summed

Dynamic Range

118dB Band 1 output
115dB Band 2 output

Distortion (THD)

<.004%

Crossover Frequency

Dependent upon loudspeaker model

Crossover Filter Type

Linkwitz Riley 24dB per octave

High Pass Filter

Dependent upon loudspeaker model;

Modified Butterworth type, 24dB per

octave

High Frequency Equalisation

Variable, dependent upon loudspeaker

model

ISC Returns

20K ohms Differential Input

ISC Return Connector Type

2 x Male 6 Pin Socket.
Pins 1 & 2 Low return
Pins 3 & 4 High return

Input /Output Connector type

XLR

Power Requirements

100–120, 220–240 VAC, 50-60 Hz, 5 VA

Weight

5 lbs/2.2 Kg

Dimensions

19"W x 1¾"H x 6"D, 482 x 44 x 155mm

This symbol indicates that a Slow Blow fuse is used in this equip-

ment. Replace with same type and value only

This symbol is intended to alert you to the presence of uninsulated

dangerous voltage within the product's enclosure that may be of

sufficient magnitude to constitute a risk of electric shock.

This symbol is intended to alert you to the presence of important

operating instructions contained in this owner's manual

WARNING SYMBOLS USED ON THIS EQUIPMENT

IMPORTANT 

- PLEASE READ THIS FIRST

This is a dual voltage unit. It is essential that you check that the voltage on

the fuseholder cover below the AC connector on the rear of the chassis is

set correctly before connecting it to AC power.

To change, pull fuseholder out and rotate 180

o

, then push in again. Do not

insert power cable into unit until voltage has been correctly set. Do not plug

power cable into AC power until voltage has been correctly set

THIS IS SET FOR

100 V AC TO 120 V

AC OPERATION

THIS IS SET FOR

220 V AC TO 240 V

AC OPERATION

Complies with 89/336/EEC EMC Directive,

amended by 92/31/EEC and 93/68/EEC and

meets the following standards:EN 55013 :

1990, Sections 3.2 and 3.5 EN 55020 :

1988, Sections 4.3, 5.4, 6.2, 7.0, 8.0.
Complies with Australian Standard AS/N25

1053