background image

ARX Systems Pty Ltd, Australia; Phone: +61-3 9555 7859 Fax: +61-3 9555 6747

Front Panel

The Workstation shall be a single channel unit in

a steel chassis nine inches deep and tworack units

high, with an extruded aluminium front panel.

The EQ section shall have 30 smooth, well

damped centre grounding sliders on standard ISO

frequencies, from 25 Hz to 20 KHz. At the 0 point

each slider shall be grounded, and in effect re-

moved from the circuit.

The Anti Feedback section shall consist of an

onboard FBX Feedback Exterminator card, with

Reset switch, an Amber LED to indicate the on-

set of clipping, and an Active or Bypassed switch.

Additionally there shall be a rear panel switch for

changing the FBX filter width.

The Limiter Threshold shall be variable by a front

panel control, from –10dB to +10dB, with a Red

Limit LED to indicate Limiting taking place.

There shall be an overall Output level control, vari-

able from –25dB to +6dB and also an overall Ac-

tive or Bypass switch on the front panel. An LED

on the front panel shall indicate AC power being

applied. On the rear panel there shall also be an

audio ground lift switch.

The unit shall have electronically Balanced inputs

and outputs, on TRS jack and XLR type connec-

tors, with passive RFI filters and an Input imped-

ance of 40 Kohms. The Input headroom shall be

+20dB, and the frequency response shall be 20

Hz to 20 KHz, ±0.5dB.

The Output impedance shall be 300 ohms, and

the maximum Output level +20dB (+10dB FBX

in), with a Signal to Noise ratio of better than –

98dB unweighted (-86dB FBX in). Total Harmonic

Distortion shall be 0.004% (0.02 FBX in) @ 0dB,

1 KHz.

AC Power shall be supplied via a removable mains

cable, connecting to an IEC connector with an in-

tegral fuse /voltage change switch on the  rear

panel.

The unit shall be the ARX AFW-1 Anti Feedback

Workstation.

<

Specifications available on disk

©1997 ARX Systems Pty.Ltd. ACN 006 471 825. All rights reserved. ARX Systems® is a Registered Trade Mark. ‘AFW-1’and

‘Anti-Feedback Workstation’ are Trademarks of ARX Systems. FBX Feedback Exterminator is a Registered Trademark of Sabine,

Inc, and is the brand name of its line of automatic feedback controllers.

Your ARX dealer is:

Rear Panel

•  30 smooth, centre grounding sliders per

channel, on standard ISO frequencies

•  Reset control for Feedback Exterminator

circuitry

•  Clip LED indicates imminent clipping, mon-

itored at all vital stages through the AFW-1

• Balanced Input and Output TRS sockets.  Tip

+ HOT, Ring – COLD, Sleeve GROUND

• Balanced Input and Output XLR connectors.

Pin 2 + HOT, Pin 3 – COLD, Pin 1 GROUND

•  Active/Bypass switch for Feedback Extermi-

nator, Limiter and Output level controls

•  Limiter Threshold and Limit LED

•  Hardwire Active/Bypass switch for unit

•  Power LED indicates AFW-1 is connected to

AC power

• Feedback Exterminator filter width switch

• Audio Ground Lift switch

• IEC 3 pin AC connector and integral

fuseholder.

Our policy is one of continuous improvement,

and therefore designs may change without

notice. However, unless otherwise stated, spec-

ifications will always equal or exceed those

previously given.

www.arx.com.au

AFW-1

Specifications

Input

40 K Ohm Balanced

20 K Ohm Unbalanced

Output

300 Ohm Balanced

150 Ohm Unbalanced

Nominal Operating Level

0 dB

Maximum Input Level

+20 dB

Maximum Output Level

+20 dB 

EQ section only

+10 dB 

FBX in

Signal to Noise Ratio

–86 dB ‘A’ Weighted

EQ section only

–98 dB Unweighted

Distortion

0.004% 

EQ section only

0.02% 

FBX in

measured@ 1 KHz, +4dB

Frequency Response

20 Hz to 20 KHz, ±0.5 dB

Equalizer Filters

30 x Constant Q on

standard ISO frequencies

FBX Filters

6 fixed, 3 dynamic

FBX Clip Indicator

Amber LED

FBX Filter Range

51Hz to 17 KHz

FBX Filter Width

1/5th or 1/10th octave

Switchable; refer manual

FBX Filter Depth

0dB to –40dB

FBX Filter Reset Time

4 seconds

Peak Limiter Threshold

Variable –10 dB to +10 dB

Limiter Status Metering

Red LED: Limiter Active

AC requirements

100–120, 220–240 VAC,

50-60Hz, 18 VA

Size

482 x 88 x 230 mm

19”W x 3½”H x 9”D

Architects’ and

Engineers’ Specifications

Reviews: