The Aruba 8360 switch is shipped with two hot-swappable, field-replaceable, AC power supplies. Each power
supply has a country-specific power cord for connection to an AC power outlet. The switch can operate with
one active power supply.
Power supply instructions
WARNING: For indoor use only. The switch, AC power cord and all connected cables are not
designed for outdoor use.
WARNING: During installation, ensure that AC power is NOT connected to the power supply
being installed.
CAUTION: Shock hazard. To completely remove power from the switch, disconnect all power
cords.
IMPORTANT: For important safety, environmental, and regulatory information, see Safety and
Compliance Information for Server, Storage, Power, Networking, and Rack Products, available at
http://www.hpe.com/support/Safety-Compliance-EnterpriseProducts
Brazil Statement
Este equipamento deve ser conectado obrigatoriamente em tomada de rede de
energia elétrica que possua aterramento (três pinos), conforme a Norma NBR ABNT
5410, visando a segurança dos usuários contra choques elétricos.)
Power supply status LED
Table 11: Power supply LED behavior
Chassis LEDs
Function
State
Meaning
Status LED
Displays power supply
status
ON green
The power supply is
operating normally.
FLASH green
The power supply is
disabled by software
which occurs when it
does not match System
Airflow definition.
ON or FLASH amber
The power supply is
experiencing a fault.
OFF
The power supply is
unpowered, inserted into
switch but no AC power
connected.
After power cord is removed, LED will light amber briefly and then go off.
Load sharing
Load sharing occurs when two power supplies are installed in the switch and turned on. Load sharing
divides the total power load of the switch among both power supplies.