1  Safety precautions.

•  Be sure to read the instructions in this section carefully before use.

•  Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded 

as very important precautions are included.

•  We also recommend you keep this instruction manual handy for future reference.

Warnings and safety.                                                                                 

Safety Symbol and Message Conventions.
Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage, 

which could result from mishandling. Before operating your product, read this manual first and understand the safety 

symbols and messages so you are thoroughly aware of the potential safety risk.

Warning.

When Installing the Unit.
•  Do not expose the unit to rain or an environment 

where it may be splashed by water or other liquids,  

as doing so may result in fire or electric shock.

•  Use the unit only with the voltage specified on 

the unit. Using a voltage higher than that which is 

 specified may result in fire or electric shock.

•  Do not cut, kink, otherwise damage nor modify the 

power supply cord. In addition, avoid using the power 

cord in close proximity to heaters, and never place 

heavy objects -- including the unit itself -- on the 

power cord, as doing so may result in fire or electric 

shock.

•  Be sure to replace the unit’s terminal cover after 

 connection completion. Because high voltage is applied 

to the speaker terminals, never touch these terminals 

to avoid electric shock.

•  Be sure to ground to the safety ground (earth) 

 terminal to avoid electric shock. Never ground to a gas 

pipe as a catastrophic disaster may result.

•  Avoid installing or mounting the unit in unstable 

 locations, such as on a rickety table or a slanted 

surface. Doing so may result in the unit falling down, 

causing personal injury and/or property damage.

WARNING

Indicates a potentially hazardous situation which, if mishandled, could result in death or serious 

personal injury. 

CAUTIoN

Indicates a potentially hazardous situation which, if mishandled, could result in moderate or 

minor personal injury, and/or property damage.

When the Unit is in Use.
•  Should the following irregularity be found during use, 

immediately switch off the power, disconnect the 

power supply plug from the AC outlet and contact your 

nearest ArtSound dealer. Make no further attempt to 

operate the unit in this condition as this may cause fire 

or electric shock.

•  If you detect smoke or a strange smell coming from 

the unit.

•  If water or any metallic object gets int o the unit

•  If the unit falls, or the unit case breaks

•  If the power supply cord is damaged (exposure of 

the core, disconnection, etc.)

•  If it is malfunctioning (no tone sounds.)

•  To prevent a fire or electric shock, never open nor 

remove the unit case as there are high voltage compo-

nents inside the unit. Refer all servicing to your near-

est ArtSound dealer.

•  Do not place cups, bowls, or other containers of liquid 

or metallic objects on top of the unit. If they acciden-

tally spill into the unit, this may cause a fire or electric 

shock.

•  Do not insert nor drop metallic objects or flammable 

materials in the ventilation slots of the unit’s cover, as 

this may result in fire or electric shock.


Summary of Contents for MIC-318

Page 1: ...results from this unit We also recommend that you keep this manual handy for future reference Check our website for any updates of this manual www artsound be house of Music NV SA Kruishoutem Belgium www artsound be Tel 32 9 380 81 80 fax 32 9 386 12 35 info artsound be operating Manual MIC 318 MICRophoNe WITh zoNe CoNTRol ...

Page 2: ... of contents 1 Safety precautions 3 2 General description 5 3 Features 5 4 Nomenclature and functions 5 4 1 Front panel 5 4 2 Rear panel 6 5 Applications 7 6 Block diagram 8 7 Specifications 9 8 Dimensional diagram 10 ...

Page 3: ...ground to the safety ground earth terminal to avoid electric shock Never ground to a gas pipe as a catastrophic disaster may result Avoid installing or mounting the unit in unstable locations such as on a rickety table or a slanted surface Doing so may result in the unit falling down causing personal injury and or property damage Warning Indicates a potentially hazardous situation which if mishand...

Page 4: ...d installing the unit in humid or dusty locations in locations exposed to the direct sunlight near the heat ers or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and c...

Page 5: ...line control Speaker zone of MX 240S can be controlled by MIC 318 Zone control circuits Speaker zones can be selected individually by means of the CHANNEL switches or altogether using the ALL CALL switch Announcements by microphone Unobtrusive and easy to use condenser type microphone which is highly sensitive and reproduces high clarity speech Pre announcement chime A two tone chime is incorporat...

Page 6: ...is possible to control speaker zone Selection and activate the chime via wired remote connection terminals for the remote 14 Chime vol Chime volume control 15 Mic vol MIC volume control 16 Master vol Master volume control All input level control 17 Chime 2 tone 4 tone chime 2 tone 4 Tone volume Control 4 2 Rear panel 13 14 15 16 17 11 12 0 10 0 10 0 10 POWER 24VDC ON OFF CHIME VOL MASTER VOL MIC V...

Page 7: ... GAIN TEL VOLUME INPUT LINE 1 REMOTE OUTPUT LINE 2 LINE TEL EMC BATT SUPPLY PRIORITY COM 100V COM 100V COM 100V COM 100V COM 100V CH1 CH2 CH3 CH4 CH5 INPUT MIC 1 MIC 2 MIC 3 MIC 4 XLR BAL 1 GND 2 HOT 3 COLD 1 2 3 REMOTE MIC VOLUME CHIME ACTIVE BATTERY 24DC SPEAKERS SPEAKERS MICROPHONE WITH ZONE CONTROL 1 2 3 MIC 2 MIC 1 MIC 4 MIC 3 ALARM IN ALARM OUT EMERGENCY PANEL AUDIO OUT R L AUDIO SOURCES MIC...

Page 8: ...MIC 318 8 D SUB 15 EB MIC VOL CHIME VOL CHIME CHIME EB EB _ 1 2 3 PIN PIN PIN 4 PIN 5 PIN 6 7 8 PIN PIN PIN 9 PIN 10 PIN 24V 15 NC 11 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 6 Block diagram ...

Page 9: ...z 20 kHz 3 dB thd Less than 0 1 s n Better than 65 dB speaker control terminal switch 5CH mic type Condenser Microphone polar pattern Unidirectional frequency response 100 Hz 16 000 Hz impedance Max 680 sensitivity 0 db 1 v 0 1pa at 1 khz 47 dB 3 dB s n ratio More than 60 dB general power source DC 24 V used by D Sub connector weight 960 g without microphone dimensions d x w x h 200 x 120 x 55 ...

Page 10: ... 10 POWER 24VDC ON OFF CHIME VOL MASTER VOL MIC VOL CHIME 2 TONE 4 TONE 1 2 3 1 GND 2 GND 3 24DC CH 1 ALL CALL CH 2 CH 3 CH 4 CH 5 CH IME TALK 18 15 12 9 6 3 0 3 6 9 18 15 12 9 6 3 0 3 6 9 OUTPUT LEVEL PUSH ON OFF 8 Dimensional diagram Keep the unit s all sides over 10 cm away from objects that may obstruct air flow to prevent the unit s internal temperature rise UNIT mm UNIT mm ...

Page 11: ......

Page 12: ...Discover the complete ArtSound range at www artsound be TM Art_Sound house Of Music NV SA Kruishoutem Belgium www artsound be Tel 32 9 380 81 80 fax 32 9 386 12 35 info artsound be ...