Place correctly

-This unit is designed to operate with a working

environment between 5°C(41°F) and 35°C(95°F).

more than 40cm

more than 20cm

more than 20cm

more than 20cm

Casters(Installed at four points on the bottom of unit)

-Do not force casters to move over carpet, nor

move the unit with water in the bucket.

(The unit may tip over and spill water.)

NOTE: Casters is optional, some models without.

Smart functions:

-Auto Shut Off

When the bucket full indicator light illiminates and the

setting humidity is reached, the unit will be shut off

automatically.

-Wait 3 minutes before resuming operation

After the unit has stopped,  it can not be restart

opertation in the first 3 minutes. This is to protect the

unit. Operation will automatically start after 3 minutes.

-Auto Defrost

When frost builds up on the evaporator coils, the

compressor will cycle off and the fan will continue to

run until the frost  disappears.

-Auto-Restart

If the unit breaks off unexpectedly due to the power

cut, it will restart with the previous function setting

automatically when the power resumes.

Summary of Contents for DHP-10R-1

Page 1: ...DM 10R Deshumidificador Manual de instrucciones Antes de usar su deshumidificador por favor lea atentamente este manual de usuario y cons rvelo para futuras referencias ESPA OL...

Page 2: ...1 Contenido 2 3 Partes Precauciones de seguridad Precauciones de uso 6 7 Funcionamiento 11 Mantenimiento Diagn stico de errores 12 13 Precauciones de uso...

Page 3: ...ontrol rejilla de salida de aire asa dep sito de agua visor nivel de agua cable de alimentaci n enchufe rejilla de entrada de aire usar cuando se almacena la unidad filtro de aire tras la rejilla sali...

Page 4: ...hufe con las manos mojadas No instale el aparato en un lugar que pueda estar expuesto a gases combustibles No coloque la unidad cerca de una fuente de calor Desconecte la alimentaci n si provienen son...

Page 5: ...enta utilizar no est adecuadamente conectado a tierra o protegido por un fusible de tiempo de retardo o un interruptor autom tico consulte la placa de identificaci n para obtener los datos el ctricos...

Page 6: ...s sensoriales o mentales reducidas o sin experiencia y conocimiento a menos que una persona responsable de su seguridad les haya dado supervisi n o instrucciones sobre el uso del electrodom stico Los...

Page 7: ...stimientos similares No coloque el cable debajo de muebles o electrodom sticos Coloque el cable lejos de reas de paso donde no se pueda tropezar No opere la unidad con un cable o enchufe da ado Desech...

Page 8: ...y se alcanza la humedad seleccionada la unidad se apagar autom ticamente Espere 3 minutos antes de reanudar la operaci n Despu s de que la unidad se haya detenido no puede reiniciarse en los primeros...

Page 9: ...ot n y configure un valor porcentual m s alto Bot n continuar Seleccione para que el deshumidificador funcione continuamente para una deshumidificaci n m xima hasta que la cubeta est llena Las almohad...

Page 10: ...posici n correcta Vac e el balde y vuelva a colocarlo en la posici n correcta Nota Cuando ocurra uno de los funcionamientos anteriores apague la unidad y verifique que no haya obstrucciones Reinicie...

Page 11: ...nstalaci n de drenaje adecuada la instalaci n de drenaje y la manguera de agua deben estar m s bajas que la salida de drenaje de la unidad Aseg rese de pasar la manguera de agua inclinada hacia abajo...

Page 12: ...la unidad principal el cuchar n y el filtro de aire Retire la cubierta de pl stico de la salida de drenaje continuo vac e el agua de la salida de drenaje continuo inclinando la unidad Envuelva el cabl...

Page 13: ...tilizar el cuchar n para recoger agua pero se retira el tap n de drenaje posterior Esto es normal La unidad tiene la caracter stica de descongelamiento autom tico Verifique la m quina de acuerdo con e...

Page 14: ...ipios establecidos como sistemas de recolecci n donde los desechos electr nicos pueden ser eliminados de forma gratuita para el usuario B Al comprar un producto nuevo puede entregar en la tienda el pr...

Page 15: ...DM 10R Dehumidifier Owner s Manual Before using your dehumidifier please read this owner s manual carefully and keep it for future reference ENGLISH...

Page 16: ...15 Contents P reparation S afety P recautions Maintenance Faults Diagnosis S ociable Remark 16 17 25 27 26 Cau tion s O p eratio n 19 21...

Page 17: ...ar f ro nt control panel air outlet grille handle bucket water level window power cord power plug air intake grille Power cord band Used only when storing the unit air filter behind the grill drain ho...

Page 18: ...not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc Do not drink or use the water drained from the unit Do not take the water bucket out during operation WARNIN...

Page 19: ...is not adequately grounded or protected by a time delay fuse or circuit breaker please refer to the nameplate for the electrical data have a qualified electrician install the proper receptacle Electri...

Page 20: ...rsons including childern with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance...

Page 21: ...o not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over Do not operate u...

Page 22: ...hen the bucket full indicator light illiminates and the setting humidity is reached the unit will be shut off automatically Wait 3 minutes before resuming operation After the unit has stopped it can n...

Page 23: ...dehumidifier on and off It illuminates when the unit is switched on and turns dark when the unit is switched off When Humidity Temperature sensor malfunction occurs the power light blinks at 5 times p...

Page 24: ...nction Protection Codes P2 Bucket is full or bucket is not in the right position Empty the bucket and replace in the right position Note When one of the above malfunctions occurs turn off the unit and...

Page 25: ...et and empty it NOTE A little water will drop down to the chassis after the bucket is removed This is a normal phenomenon Please the user handle it himself water outlet 2 Continuous draining Water can...

Page 26: ...ff the unit wait one day before emptying the bucket Clean the main unit bucket and air filter Remove the plastic cover of the continuous drain outlet empty the water of the continuous drain outlet by...

Page 27: ...loose Intend to use the bucket to collect water but the back drain plug is removed This is normal The unit has Auto defrost feature Did not allow enough time to remove the moisture Make sure there ar...

Page 28: ...lished collection systems where electronic waste can be disposed of at least free of charge to the user B When buying a new product the retailer will take back the old product at least free of charge...

Reviews: