![ARTRAY ARTCAM-130MI-NIR Instruction Booklet Download Page 5](http://html1.mh-extra.com/html/artray/artcam-130mi-nir/artcam-130mi-nir_instruction-booklet_2978812005.webp)
-5-
4-3 EXTERNAL TRIGGER
Standard Frame Timing
T = Reset Time
TRIGGER
VD
HD
PCLK
row 16
row 17
row 18
row 19
row n-1
row n
row
ǫ
T2
Remark1 : T is the time required for reset. Time required for each model is as below.
Start reset from trailing edge of trigger terminal.
ARTCAM-130MI ---> 70msec approx.
ARTCAM-200MI ---> 100msec approx.
ARTCAM-300MI ---> 170msec approx.
1. Timing
2. External trigger hardware
VCC
2.4
K
ǡ
External BNC connector
Input
㧦
12
㨪
24VDC
Current in either direction
PC841
˴
photo coupler
10K
ǡ
GND
External trigger
(These values are for dafault resolution)
Remark2 : The actual time for capturing is at least twice as long as the time
indicated in Remark1 (@ 8 bits).
T2 is the transfer time. IsCaptureFinish() is returned when T2 is completed.
Remark3 : Serial NO0963 has been altered to photo-isolation type as below.
The following is the internal equivalent circuit.