Rail-Contact User Guide

Please read these instructions before using the product.

This product has been designed & manufactured for professional use only. 

It should only be installed by a suitably qualified technician and in accordance with 

electrical regulations in the country of use.

Unless directed in the instructions there are no user serviceable parts inside the 

outer case of this product.

Always disconnect from the power supply when not in use.

Any specific IP rating, where appropriate, is given in the instructions. Unless 

otherwise stated this product is designed for indoor use only. If used outdoors it 

MUST be installed in an appropriate IP rated cabinet. Do not allow this product to be 

exposed to rain or moisture. Do not allow liquid to penetrate the product.

Please recycle all packaging.

Copyright © Artistic Licence Engineering Ltd. All rights reserved.

Download the user guide by scanning the following QR code:

Summary of Contents for Rail-Contact

Page 1: ...Artistic Licence Rail Contact User Guide Rail Contact Version 1 1 User Guide...

Page 2: ...inside the outer case of this product Always disconnect from the power supply when not in use Any specific IP rating where appropriate is given in the instructions Unless otherwise stated this product...

Page 3: ...bles Power 9 24VDC Input 10W Max Duty Cycle 80 Opto Inputs Max voltage set by internal resistors See manual for details DMX Input Channels will be concatenated with output Max Wire Size 2 5mm2 Remove...

Page 4: ...ects to Ground Power Input Overview Rail Contact is a DIN rail mounted device that provides 8 contact closure inputs whose state can be translated into a DMX512 value This enables a DMX512 controller...

Page 5: ...ched to channels 9 to 16 It is expected that in normal usage the opto isolated inputs will be used to provide protection from electrical noise arising from long cable distances to powered equipment se...

Page 6: ...ing when Rail Contact is used in isolated mode The example shows the wiring when Rail Contact is used in non isolated mode Application Diagram Wiring Diagrams Rail Contact Rail Contact Terminated DMX...

Page 7: ...onnector 1 pin screw terminal 1 no current limited to 250 mA y y Input power max 10 W y y Duty cycle 80 25 C y y DC fuse internal resettable fuse for control electronics DMX512 input output y y Protoc...

Page 8: ...anufactured or sold by Artistic Licence Engineering Ltd are fully compliant with the appropriate CE FCC and RoHS regulations Product specific information is available on request Waste Electrical Elect...

Reviews: