35
Parameter Description
Break
MaB Start
Code
ISD Slots Data
Slots
Data
Slot
Value
MbB
Bad SIPs
Micro-Scope 3c
transmits SIP packets
that have good timing
but contain bad data.
This can be used to
check that a DMX
receiver correctly
rejects non-zero start
codes. Illegal packet.
200us
20us 207
0
201
200
85
16us
Break only Micro-Scope 3c
continuously sends a
break with no slots.
Some DMX
responders can be
upset by this. Legal
packet.
200us
n/a
n/a
n/a n/a
n/a
n/a
n/a
Break+Strt Micro-Scope 3c
continuously sends a
break and start code
with no slots. Some
DMX responders can
be upset by this. Legal
packet.
200us
20us 0
n/a 1
0
n/a
n/a
Long pack
Micro-Scope 3c sends
packets with 1000
data slots. This is
primarily useful for
development testing.
Illegal packet
200us
20us 0
0us 1001 1000 0
16us
Short pack Micro-Scope 3c sends
packets with 8 data
slots but very fast
timing and violates
the standard. This is
primarily useful for
development testing.
Illegal packet
200us
20us 0
0us 9
8
0
16us
Short Brk
Micro-Scope 3c sends
packets with a short
break. This is primarily
useful for
development testing.
Illegal packet
72us
20us 0
0us 513
512
0
16us