3.6 Serial Port
The Matrix-752 has two serial ports:
One RS-485/RS-232 ports, Default setting is RS-485.
One RS-232 port (TX/RX)
RS-485 is designed without isolation that automatically direction controlled via
software
The pin assignment is shown as following table:
Port No.
Pin1
Pin2
Pin3
Pin4
Pin5
Serial Port 1
RS-485
D+
D-
--
--
GND
RS-232 (1)
TX1
RX1
--
--
GND
Serial Port 2
RS-232 (2)
--
--
TX2
RX2
GND
Enable/Disable Termination resistor for RS-485 (JP4)
The Matrix-752 provides on-board 120Ohm termination resistor for each RS-485
port. To enable the termination resistor, please remove the upper cover of the Matrix-
752, and the adjust the associated jumper to short as below:
Termination Resistor Disabled (default)
Termination Resistor Enabled
1 2 3
1 2 3
JP4
RS485(D+/D-)
Or RS232(TX1/RX1)
RS232(TX2/RX2)
GND