Thereafter, the RTS line must be switched with a period of approximately 200ms,
independent of all other communication. Delay of this switching will result in abortion of the
communication connection.
11.2
Parameter Upload
The parameter set has to be uploaded before any current pulse may be generated.
In the upload process all data is send byte by byte. After receiving one byte the device returns
the received byte (echo). Following verification, the next byte can be send. An error in data
transfer can be realized in this manner.
Note that all data must be uploaded in the order described, even if not all parameters are used
in an operating mode. The general data upload starts with “@P”.
Table 15: Upload Parameters
Byte No. Description
Range
Meaning / Conversion
1
Pulse repetition (High Byte)
1-10,000
10µs – 100ms
100µs-1s
1ms-10s
2
Pulse repetition (Low Byte)
3
Pulse Width (High Byte)
1 – 40,000
50ns – 3s
4
Pulse Width (Low Byte)
5
Minimum Current (High Byte)
0 – 4,095
0-200A (48,8mA/bit)
6
Minimum Current (Low Byte)
7
Maximum Current (High Byte)
0 – 4,095
0-200A (48,8mA/bit)
8
Maximum Current (Low Byte)
9
Current Steps (High Byte)
1 – 1,000
10
Current Steps (Low Byte)
11
Bias (Low Byte)
0 – 4,095
0-1A (0,244mA/bit)
12
Bias (High Byte)
13
Number of cycles (MSB Byte)
1
-
1,000,000,000
14
Number of cycles (middle Byte)
15
Number of cycles (middle Byte)
16
Number of cycles (LSB Byte)
17
Cycling Mode
0 – 2
0: parallel
1: seriel
2: Burstmode
21
The repetition range depends on clock parameter.
22
The pulse width depends on this parameter and clock parameter as well (s. section: clock
parameters).
23
200A is just an example. The real value depends on the LDD type.
Summary of Contents for LDD100-F Series
Page 25: ...LDD100 Operating Instructions 25 72 5 1 1 Safe Operating Area LDD100 F040...
Page 27: ...LDD100 Operating Instructions 27 72 5 2 1 Safe Operating Area LDD100 F120...
Page 29: ...LDD100 Operating Instructions 29 72 5 3 1 Safe Operating Area LDD100 L040...
Page 31: ...LDD100 Operating Instructions 31 72 5 3 2 Safe Operating Area LDD100 L120...
Page 33: ...LDD100 Operating Instructions 33 72 5 4 1 Safe Operating Area LDD100 L200...
Page 35: ...LDD100 Operating Instructions 35 72 5 5 1 Safe Operating Area LDD100 XL040...
Page 37: ...LDD100 Operating Instructions 37 72 5 6 1 Safe Operating Area LDD100 XL120...
Page 39: ...LDD100 Operating Instructions 39 72 5 7 1 Safe Operating Area LDD100 XL200...
Page 41: ...LDD100 Operating Instructions 41 72 5 8 1 Safe Operating Area LDD100 XL400...
Page 43: ...LDD100 Operating Instructions 43 72 5 9 1 Safe Operating Area LDD100 XL600...