background image

 

Connections 

 

 

 

-

 

Microphone out: XLR connector of the microphone installed in the 
DynamicTalk 

-

 

12V DC IN: XLR4 connector to the power supply 

-

 

1,2: Ground 

-

 

3,4: 12VDC 

-

 

GPI/GPO: SubD 9 pins female connector to contact close external 
functions. Connect the external UP/DOWN push button to this 
connector 

Pin Function 
1,6 

Contact close of the customised push button 
on upper cover plate (central button). 
100mA Max. 

8,9 
Only in conference mode 

Contact close of the TALK push button on 
upper cover plate, only in conference mode. 
This function is not working when the device 
is configured in PA mode 
100mA Max. 


Only in conference mode 

Activates the ring RED LED in conference 
mode, connecting to GPI ground 


Only in conference mode 

Activates the ring GREEN LED in conference 
mode, connecting to GPI ground 

Connect this pin to GPI ground to rise up 
the microphone 

Connect this pin to GPI ground to down the 
microphone 

7 GPI 

ground 

 
NOTE: In conference MODE, if the 2 and 3 pin are not connected to 
ground, the ring LED is off. 

Summary of Contents for AHDTLM UC

Page 1: ...User manual __________________________________________________ AHDTLM UC Motorized microphone system for underneath installation...

Page 2: ...screens are a part of the interior design as well as essential communication tools Please read this installation and operating instructions carefully and keep them in a safe place for a future consult...

Page 3: ...3 Table of contents FEATURES 6 BOX CONTENTS 6 CONTROLS 7 CONNECTIONS 8 AHNET PROTOCOL 10...

Page 4: ...sk of electronic shock This symbol draws attention to important use and maintenance instructions in the manual that accompanies the unit This symbol indicates that the equipment conforms to the norms...

Page 5: ...outlet must be in an easily accessed place Environment Install the equipment on an elevated flat surface Install the equipment in a ventilated area Avoid exposing the equipment to Rain or water Excess...

Page 6: ...Dynamic LED ring for ready to talk and talk indications Up Down movement for external push buttons Down control movement for cover plate button Push button to MUTE function in PA mode or used to GPO i...

Page 7: ...that the mute is not active and you can talk to the audience Press once the button the ring LED change to green indicating that the MUTE is active and the microphone is not working Conference mode In...

Page 8: ...nly in conference mode Contact close of the TALK push button on upper cover plate only in conference mode This function is not working when the device is configured in PA mode 100mA Max 2 Only in conf...

Page 9: ...is the number of the device into the RS422 addressable bus Microphone length setting procedure Dynamic Talk is designed to work with microphones of different lengths Two signs to identify an incorrect...

Page 10: ...answer Pins 3 6 the units receive orders Protocol to control the device by addressable RS422 bus You can connect up to 30 dvices on the same RS422 bus You can use a AH Interface Ethernet to control t...

Page 11: ...XX 04 00 00 BUTTON UN LOCK FB XX 04 00 00 FA XX 14 00 00 INQUIRY CONTROL BYTE FB XX 14 CB1 CB2 XX Number of the DynamicTalk address Up to 30 units for each RS422 BUS CB1 Response in 8 bites of the dev...

Page 12: ...12...

Page 13: ...to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local author...

Page 14: ...oth freight and insurance will be paid by Albiral Display Solutions S L Although Albiral Display Solutions S L pays for transport and insurance cost Albiral Display Solutions S L will not be responsib...

Page 15: ...15...

Page 16: ...Hip lit de Voltreg 08512 Barcelona Spain tel 34 93 850 23 76 23 83 fax 34 93 850 25 50 web www arthurholm com e mail marketing arthurholm com This manual can be modified without previous notice Arthur...

Reviews: