background image

User manual

AH17D X2HDGA TALK
AH22D X216GA TALK

Retractable monitors for furniture integration with 
integrated DynamicTalk

Summary of Contents for AH17D X2HDGA

Page 1: ...User manual AH17D X2HDGA TALK AH22D X216GA TALK Retractable monitors for furniture integration with integrated DynamicTalk ...

Page 2: ......

Page 3: ...ITY 6 SAFETY INSTRUCTIONS 7 APPLICATIONS 8 BOX CONTENTS 8 FEATURES 9 CONTROLS 10 OSD MENU 14 INPUT CONNECTORS 17 DYNAMICTALK HANDLING 21 WARNING 22 MONITOR AHnet PROTOCOL 23 DYNAMICTALK AHnet PROTOCOL 26 INPUT SIGNALS 29 PRODUCT WARRANTY 31 ...

Page 4: ......

Page 5: ...the screens are a part of the interior design as well as essential communication tools Please read this installation and operating instructions carefully and keep them in a safe place for future reference We remain at your entire disposal if you have any suggestions that would help us improve our products Henrik Holm General Manager ...

Page 6: ...s un insulated voltages inside some of the components of sufficient magnitude to expose people to risk of electronic shock This symbol draws attention to important use and maintenance instructions in the manual that accompanies the unit This symbol indicates that the equipment conforms to the norms established by the European Community ...

Page 7: ...t be connected to an electrical outlet with grounding connection protection The operating electrical outlet must be in an easily accessed place ENVIRONMENT Install the equipment on an elevated flat surface Install the equipment in a ventilated area Avoid exposing the equipment to Rain or water Excessive heat cold or humidity Areas exposed to direct sunlight Dirty areas Equipment generating strong ...

Page 8: ...y be disconnected in order to save energy and preserve panel life By pressing the rear button located on the table cover plate the TFT panel raises up into the working position raised and tilted The TFT power is then restored This TFT LCD product range is specially designed for desk integration in Conference rooms Meeting rooms Board rooms Auditoriums Information desks Training rooms BOX CONTENTS ...

Page 9: ...w radiation Quick response time Data inputs DVI I DVI D HDCP compliant Upper cover plate in brushed stainless steel with outgoing hatch Monitor housing made of solid mechanized aluminium in anodized finish and front glass Electrical powered lift system with variable speed Addressable RS422 monitor control by AHnet protocol RJ45 connector CAT5 Dynamic LED Ring for Ready to Talk and Talk indicators ...

Page 10: ...CE Signal input selection RIGHT Cursor control right on OSD menu LEFT Cursor control left on OSD menu UP Cursor control up on OSD menu DOWN Cursor control down on OSD menu SEL Selects the OSD menu function When the OSD menu is not active auto adjusts the function for ARGB analogue input signal MENU Activates the OSD menu Exits OSD menu when is active POWER LED SOURCE RIGHT LEFT UP DOWN SELECT MENU...

Page 11: ...ontrol left on OSD menu RIGHT Cursor control right on OSD menu OK Selects the function on OSD menu MONITOR ADDRESS Below the monitor there is a screen to to configure the monitor address on the RS422 AHnet Changing the monitor address Push OK One beep sounds Change the monitor address using the UP DOWN buttons Push OK 2 beep sounds indicating that the new address has been saved IR SENSOR The IR se...

Page 12: ... the cover plate To retract the monitor display press the front button 1 on the right hand side of the cover plate 2 Raising the monitor It is recommended that no objects or parts of the body that could obstruct the rising of the display are not on the top of the cover plate To rise up the monitor display press the rear button 2 on the right hand side of the cover plate Permanent pressing this but...

Page 13: ...tivate de Mute function and silent the microphone which will be indicated by the green LED ring Conference mode In conference mode the microphone is controlled by the external conference system In this case ths button then has no function and the contact close of the push button is present on the SubD9 control connector GPO In this case there are two GPO buttons available 6 Dynamic LED Ring The sy...

Page 14: ...plete list of all the functions available for the monitor Press the SEL button to enable the item When a function is selected press the LEFT and RIGHT buttons in order to change the parameter of the function Press the Menu button to access to the main menu PICTURE CSM Configuration of the image colour Cool Normal Warm User manually adjustment of red green and blue colours PSM Configuration of the ...

Page 15: ...l screen but keeps the original aspect ratio of the input image 4 3 Shows the image on screen with 4 3 aspect 1 1 Shows the image on screen with the original resolution Backlight Adjust the backlight of the screen Flip Flip the image on screen Off Image with no flip 1 Vertical flip 2 Horizontal flip 3 Rotate OSD Flip Flip the menu on screen OSD Off Image with no flip 1 Vertical flip 2 Horizontal f...

Page 16: ...he clock Auto Adjust Auto adjust the image on screen Reset PC image control reset 1050 Selection of the exact input resolution Only for ARGB analogue input 1400 x 1050 1680 x 1050 WXGA Selection of the exact input resolution Only for ARGB analogue input 1024 x 768 1280 x 768 1360 x 768 BG Colour Background colour of the screen when there is no input signal The monitor only goes to stand by mode wh...

Page 17: ...tor XLR 4 connector 1 2 Ground 3 4 12Vdc GPI Monitor external contact close control SubD9 female 1 GPI1 2 GPI1 3 GPI2 4 GPI2 5 GPI3 6 GPI3 7 N C 8 12Vdc 600mA max 9 Ground Use GPI1 1 12Vdc 2 Ground to open the monitor Use GPI3 6 12Vdc 5 Ground to close he monitor Termination Activate ON the termination ONLY on the last unit of the RS422 bus AHnet RJ45 CAT5 connector for addressable RS422 control T...

Page 18: ...Contact close of the TALK push button on the upper cover plate only in conference mode This function does not work when the device is configured in PA mode 100mA Max 2 Only in conference mode Activates the RED LED ring in conference mode connecting to GPI ground 3 Only in conference mode Activates the GREEN LED ring in conference mode connecting to GPI ground 4 Connect this pin to GPI ground to RI...

Page 19: ...he contact close is available on GPO connector and the LED ring is controlled externally GPI 4 5 Factory only Leave those dip switches off 6 Termination of the RS422 bus Configure to ON only on the last device of the RS422 bus AHnet RJ45 CAT5 connector for addressable RS422 control There is a loop through connector to use as signal RS422 output You can connect up to 30 devices on the same RS422 bu...

Page 20: ...the Monitor Configurator Tool but there is also a quick procedure that doesn t require the use of a PC or cable 1 Disconnect the Power connector 2 Set switch 5 to ON position 3 Set the length of the microphone in the rotatory switch in cm For instance if the microphone is 40cm set the rotatory switch as tens 4 unit 0 4 Connect to Power There will be a 5 beep sound 5 Disconnect Power 6 Set switch 5...

Page 21: ...usage of the DynamicTalk microphones To avoid any product malfunctions do not attempt to bend the microphone to the incorrect angle or outside the microphone s working area as indicated on the picture below Please note that ware to the microphone and pop screen surface can occur ...

Page 22: ...se the monitor near water If any liquid is accidentally spilled on the surface cut the power supply and dry it with a cloth Don t restore the power supply until it s completely dry Do not insert objects of any kind into the cabinet slots as they may touch dangerous voltage points which can be harmful or fatal or may cause electric shock fire or equipment failure If the monitor or glass is broken d...

Page 23: ...Data RX 4 NC 5 NC 6 Data RX 7 NC 8 NC CONNECTION Pins 1 2 The units respond Pins 3 6 The units receive instructions Protocol to control the monitor by addressable RS422 bus You can connect up to 30 monitors on the same RS422 bus You can use a AH Interface Ethernet to control the RS422 bus The units should have a set address and the address must start by 1 Maximum cable length between ends 500m 164...

Page 24: ...SCREEN OFF FB XX 02 00 00 FA XX 03 01 00 DVI A SELECTION FB XX 03 01 00 FA XX 03 00 00 DVI 1 SELECTION FB XX 03 00 00 FA XX 03 03 00 DVI 2 SELECTION FB XX 03 03 00 FA XX 04 01 00 BUTTON LOCK FB XX 04 01 00 FA XX 04 00 00 BUTTON UNLOCK FB XX 04 00 00 FA XX 05 00 00 AUTO CONFIG LCD FB XX 05 00 00 FA XX 14 00 00 INQUIRY CONTROL BYTE FB XX 14 CB1 CB2 XX Number of the monitor address Up to 30 monitors ...

Page 25: ... 1 SCREEN ON 1 SCREEN OFF 0 DVI A DVI 1 D 0 0 DVI 2 D 1 1 PROTECTION STOP 1 0 1 MONITOR OK 0 CB2 BITE 7 6 5 4 3 2 1 0 BUTTON LOCK 1 BUTTON UNLOCK 0 To send an order to all the monitors you must use the address 249 Dec Byte1 F9 Hex Byte1 In this case the units do not send a reply ...

Page 26: ...11 Data RX 12 NC 13 NC 14 Data RX 15 NC 16 NC CONNECTION Pins 1 2 The units respond Pins 3 6 The units receive instructions Protocol to control the unit by addressable RS422 bus You can connect up to 30 units on the same RS422 bus You can use a AH Interface Ethernet to control the RS422 bus The units should have a set address and the address must start by 1 Maximum cable length between ends 500m 1...

Page 27: ...FA XX 01 00 00 GO DOWN FB XX 01 00 00 FA XX 02 01 00 MUTE ON Only in PA mode FB XX 02 01 00 FA XX 02 00 00 MUTE OFF Only in PA mode FB XX 02 00 00 FA XX 04 01 00 BUTTON LOCK FB XX 04 01 00 FA XX 04 00 00 BUTTON UNLOCK FB XX 04 00 00 FA XX 14 00 00 INQUIRY CONTROL BYTE FB XX 14 CB1 CB2 XX Number of the DynamicTalk address Up to 30 units can be connected for each RS422 BUS CB1 Response in 8 bits of ...

Page 28: ... TOP POSITION BITE 1 DOWN POSITION BITE 2 1 MUTE ON BITE 3 1 BUTTON LOCK BITE 4 BITE 5 BITE 6 BITE 7 1 FAILURE IN THE SYSTEM To send an order to all the devices you must use the address F7 Hex Byte1 In this case the units do not send a reply ...

Page 29: ...x600 75Hz 46 875 75 000 Progressive 1024x768 60Hz 48 363 60 005 Progressive 1024x768 70Hz 56 476 70 070 Progressive 1024x768 75Hz 60 023 75 030 Progressive 1280x720 60Hz 44 772 59 855 Progressive 1360x768 60Hz 47 72 59 799 Progressive 1280x1024 60Hz 63 981 60 020 Progressive 1600x1200 60Hz 75 000 60 00 Progressive 1680 x1050 60Hz 64 742 59 946 Progressive 1920x1080 60Hz 66 647 59 98 Progressive ...

Page 30: ...elp to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling Please contact your local authority for further details of your nearest designated collection point Penalties may be applicable for incorrect disposal of this waste in accordance with national legislation For business users in t...

Page 31: ... faulty electronic and or mechanical components arising from incorrect installation unauthorized modification and inadequate transport or as a result of atmospheric phenomenon B Labour Albiral Display Solutions S L covers labour costs for replacement of any defective parts in accordance to paragraph A during the period of this warranty C Transport costs I In the case that a manufacturing defect oc...

Page 32: ...9367 A1 MU 17301 ES00 MU 17322 ES00 MU 17376 ES00 MU 17403 ES00 This manual can be modified without previous notice ENG February 2016 Fàtima 25 Sant Hipòlit de Voltregà 08512 Barcelona Spain tel 34 93 850 23 76 23 83 fax 34 93 850 25 50 23 72 web www arthurholm com e mail marketing arthurholm com ...

Reviews: