Operator’s Manual 

Synergy

Resection™

 Wireless Footswitch  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AR-8315W 

 

DFU-0320-3 Rev. 0   

 

 

 

 

 

 

09/2019 

 

Summary of Contents for Synergy Resection AR-8315W

Page 1: ...Operator s Manual SynergyResection Wireless Footswitch AR 8315W DFU 0320 3 Rev 0 09 2019 ...

Page 2: ...DFU 0320 3 Rev 0 2 of 20 This page intentionally left blank ...

Page 3: ...ntents English Guarantee 4 Safety 5 Definitions of Terminology 6 Transmitter Receiver Pairing 9 Electromagnetic Interference 11 Equipment Symbols 12 Receiver 13 Transmitter 14 Battery Replacement 16 Cleaning 17 Specifications 18 ...

Page 4: ...ll correspondence covering the instrument should specify the model and serial number CAUTION In the United States of America Federal Law restricts this device to sale by or on the order of a physician Caution Federal Law Restricts this device to sale by or on the order of a Physician Arthrex Inc 1370 Creekside Blvd Naples FL 34108 1945 USA Toll Free 800 934 4404 www arthrex com Arthrex GmbH Erwin ...

Page 5: ...lent safety requirements of this equipment may lead to a reduced level of safety of the resulting system Consideration relating to the choice shall include Use of the accessory in the PATIENT VICINITY Evidence that the safety certification of the ACCESSORY has been performed in accordance to the appropriate IEC 60601 1 and or IEC 60601 1 1 harmonized national standard Periodically whenever the int...

Page 6: ...e to specific features of the footswitch WARNING A WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION A CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Cautions are also used to avoid damage to equipment IMPORTANT An IMPORTANT notice indicates an emphasized note It ...

Page 7: ...20 3 Rev 0 7 of 20 Interfacing to Equipment Footswitch receiver must be connected with equipment using the 805 W49 cable assembly Be certain to consult manufacturer s specifications to maintain safe operation ...

Page 8: ... representative for service The footswitch should not be used if it is not working properly IMPORTANT Loss of Signal If the receiver does not receive a signal from the transmitter for a period of 500ms it will shut off the outputs However once the transmission is restored the receiver will function normally The RF wireless foot switch operates in a 360 degrees mode of operation However every appli...

Page 9: ... via a footswitch port Consult the User Guide for the shaver console AR 8305 DFU 0213 XX for more information if needed A The GREEN Power LED should be on indicating connection to the console B All WHITE Directional LED s should be off and C The RED Battery LED may be on refer to step 9 off or flashing at this point D Pairing Button 3 To begin the footswitch and receiver pairing process position t...

Page 10: ...ss 6 Once the pairing process is completed the RED Battery LED should either A Turn OFF if pairing was successful B Flash slowly 50 duty cycle 1Hz if pairing was unsuccessful or C Flash rapidly for the remainder of the pairing process then flash slowly if no footswitch is found 7 If pairing is unsuccessful repeat steps 1 5 paying particular attention to the NOTE in step 1 and to step 3 8 Following...

Page 11: ...IC 6992A 24 This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the device This device shall be marked with the CE0086 mark as shown in accordance with Articles 19 and 20 of the ...

Page 12: ... Table 1 2 Equipment Symbols ATTENTION Consult accompanying documents ALTERNATING CURRENT AC EARTH GROUND O POWER OFF disconnection from the mains I POWER ON connection to the mains LOW BATTERY FOR INDOOR USE ONLY TYPE B EQUIPMENT Type B equipment is suitable for intentional external and internal application to the patient excluding direct cardiac application ...

Page 13: ...On c RED Battery Status LED Indicator Off It is paired with a footswitch with good battery level Flash Slowly 50 duty cycle 1Hz It is not paired with any footswitch Flash Rapidly Pairing in process Solid Red Footswitch has low 2 0V battery d Pairing Button Pushbutton behind the wireless symbol Press and hold until RED Battery Status LED begins to flash rapidly to start the pairing process Refer to...

Page 14: ...DFU 0320 3 Rev 0 14 of 20 Transmitter Footswitch 1 2 3 4 5 8 6 7 ...

Page 15: ...e same thing Name Description 1 Left Pedal REVERSE 2 Center Pedal OSCILLATE 3 Right Pedal FORWARD 4 TOGGLE Pushbutton 5 CRUISE Pushbutton in GFS Mode SPEED Pushbutton in SFS Mode 6 GFS SFS Mode Pushbutton Switches between GFS gas pedal footswitch mode and SFS standard footswitch mode 7 Pairing Pushbutton 8 Battery Tube ...

Page 16: ...ot to damage the O ring seal on the battery cap The O ring seal should be replaced whenever it is damaged or its integrity is in question Battery Leakage If the transmitter will not be used for an extended period of time remove the batteries to prevent damage due to possible battery leakage Battery disposal Follow the battery manufacturer s recommendations or your facilities policy for the disposa...

Page 17: ...tely immersed briefly Dampen a non abrasive cloth with one of the following products then wring out until slightly wet and gently rub soiled area until clean Isopropyl alcohol Soap and water Cidex Sodium Hypochlorite 5 25 Bleach diluted 10 1 Receiver CAUTION The receiver is IPX1 rated and cannot be immersed Dampen a non abrasive cloth with one of the following products then wring out until slightl...

Page 18: ...any activation depending on environmental conditions o 2000 hours of operation typical 50 duty cycle depending on environmental conditions Power requirements receiver 12VDC 200mA Max Receiver Output o Linear VOUT 0 10V o Switched VOUT Active High Open Collector To GND EN 60529 Degree of Protection IP68 Transmitter Size Transmitter W x D x H 17 5 in x 9 in x 2 25 in 44 45 cm x 22 86 cm x 5 715 cm R...

Page 19: ...DFU 0320 3 Rev 0 19 of 20 This page intentionally left blank ...

Page 20: ...ervice 1 800 934 4404 Arthrex Inc Toll Free Technical Support 1 800 391 8599 Monday through Friday 8 00 AM 8 00 PM ET www arthrex com Arthrex GmbH Erwin Hielscher Strasse 9 81249 München Germany Tel 49 89 909005 0 www arthrex de All rights reserved Printed in USA ...