ARTHREX

®

 CONTINUOUS WAVE

 4 SET-UP AND OPERATION

Arthrex, Inc. 
1370 Creekside Blvd. 
Naples, FL 34108-1945 USA 
Toll Free: 1 (800) 934-4404 
www.arthrex.com

Arthrex GmbH 
Erwin-Hielscher-Strasse 9 
81249 München, Germany 
Tel: +49 89 909005-0 
www.arthrex.de

Arthrex Tech Support: 
+1-888-420-9393 

+49 89 90 90 05 8800

For more information consult the User's Guide and the Directions for Use supplied 

with the pump or tubing sets.

Summary of Contents for CONTINUOUS WAVE

Page 1: ... 1945 USA Toll Free 1 800 934 4404 www arthrex com Arthrex GmbH Erwin Hielscher Strasse 9 81249 München Germany Tel 49 89 909005 0 www arthrex de Arthrex Tech Support 1 888 420 9393 49 89 90 90 05 8800 For more information consult the User s Guide and the Directions for Use supplied with the pump or tubing sets ...

Page 2: ...e of flow for improved control of debris removal Only available when using DualWave outflow Shaver Suction Toggle Allows switching be tween four preset shaver suction levels Only available when using DualWave outflow Lavage Pressure Decrease Shaver Suction Toggle Rinse Pressure Increase Run Stop Autoclavable Remote Foot Control ...

Page 3: ...sert the green tubing hub next to the green mark Wrap the thicker tubing between the hubs and around the rollers 1 6 8 2 7 3 4 5 Rollers Inflow door Tubing sensor coupler Clear tubing hub Close inflow latch Remote foot switch connector Power button a b d c Turn on the system and wait until the self diagnostic testing has finished before attaching the tubing Stretch the thicker tubing to insert the...

Page 4: ...W ONLY USER INTERFACE Stopped Running Menu Boost Control Set Pressure Pressure Decrease Lavage Pressure Increase Run Stop Run Stop Pressure Reading Run Time Resets after power down Inflow Only Fluid Used Flow Rate ...

Page 5: ...ergy imaging console for the heads up display Power on the Synergy Resection Console 2 1 4 Power on the CW4 3 For the Synergy heads up display use the AR 3200 1040 accessory cable kit to connect the CW4 to camera console Only 1 cable is needed to connect the CW4 to the camera console See IFU 950 0052 00 for more detail 2 3 NOTE Start with all units turned off CW4 Synergy ...

Page 6: ...NOTES ...

Page 7: ...oudy Does not pump when activated Door Open Inadequate pressure No Low Flow 1 Check for error messages 2 Check that all tubing clamps are open 3 Check the settings for flow and pressure 4 Check if the tubing is pinched kinked or blocked 5 Check that tubing seats correctly over the rollers 6 Verify use of high flow cannulas 7 If failure remains return to Arthrex for repair 1 If failure remains incr...

Page 8: ...judgment in making any final determinations in product usage and technique In doing so the medical professional should rely on their own training and experience and should conduct a thorough review of pertinent medical literature and the product s Directions For Use http www arthrex com imaging resection fluid management View U S patent information at www arthrex com corporate virtual patent marki...