USER MANUAL

ARTFOX Pointy 10R

Summary of Contents for Pointy 10R

Page 1: ...USER MANUAL ARTFOX Pointy 10R ...

Page 2: ...the mains 6 3 2 Changing the lamp 7 3 3 Lamp adjustment 8 3 4 Replacing rotating gobos 10 3 5 Rigging the fixture 11 3 6 DMX 512 connection 13 4 DMX Protocol 14 5 Operation Menu 17 6 Technical Specifications 19 7 Maintenance and cleaning 21 8 Photometric diagrams 23 ArtFox Pointy 10R Beam Spot Wash 3 in 1 3D effect ...

Page 3: ...nel of the fixture This fixture should be operated only from the type of power source indicated on the marking label If you are not sure of the type of power supplied consult your authorized distributor or local power company Always disconnect the fixture from AC power before cleaning removing or installing the fuses or any part The power plug has to be accessible after installing the fixture Do n...

Page 4: ...roximately 20 minutes prior to manipulate with it This fixture should not be placed in a built in installation unless proper ventilation is provided Only operate the fixture after having checked that the housing is firmly closed and all screws are tightly fas tened Always use a secondary safety cable when mounting this fixture Make sure that the area below the installation place is blocked when ri...

Page 5: ...To unlock the head move these latches to unlock positions before operating the fixture Rear panel of the base 1 Power In 2 Power On Off 3 3 pin DMX Out 4 5 pin DMX Out 5 Fuse Holder 6 3 pin DMX In 7 5 pin DMX In Front panel of the base 1 LCD touch screen 2 FUNCTION button 3 UP button 4 DOWN button 5 ENTER DISPLAY ON button The ENTER DISPLAY ON button also serves for switching the display on when t...

Page 6: ...ight Monster is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 100 240 Volts This fixture must be earthed To use the fixture a plug must be fixed The correct assembly of a sufficient plug may be done by professional persons only The conductors in the cable are marked by the following table Core EU Core US Connection Plug Terminal Marking Br...

Page 7: ...t the lamp into lamp compartment until it snaps into spring locks 5 Do not install a lamp with a higher wattage A lamp like this generates temperatures the device is not designed for Damages caused by non observance are not subject to warranty Please follow the lamp manufacturer s notes Warning do not touch the lamp s envelope with bare hands Should this happen clean the bulb with a cloth soaked i...

Page 8: ... the fixture from mains 3 Loosen two quarter turn fasteners 1 on a lamp cover and remove the lamp cover 2 to get into lamp compartment 4 Move the lamp into desired position by using a suitable screwdriver inserted in the appropriate slots A B 5 Re insert the lamp cover 2 and tighten the two quarter turn fasteners 1 6 Connect the fixture to the mains and check if the adjustment has been correctly m...

Page 9: ...d hot spot may move during the first 100 hours of the lamp operation lamp stabilizes its burning and the lamp adjusting has to be repeated In some cases the lamp adjusting has to be made every 100 hours of lamp operation ...

Page 10: ...the gobo holder from the rotation gobo wheel 4 Carefully remove the gobo and the spring gobo lock from the gobo holder by pushing to the gobe from the side without toothed wheelt Do not touch the surface of the pattern of the glass gobo use a suitable glove Be careful Glass 5 Insert the new gobo glazy side towards the lamp Insert the spring gobo lock to secure it in the gobo holder 6 Insert the go...

Page 11: ...ications do not attempt the installation yourself but use a help of professional companies CAUTION Fixtures may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do not install the fixture The fixture has to be installed out of the reach of public The fixture must never be fixed swinging freely in the room Danger of fire When installing th...

Page 12: ...and tighten fully clockwise 3 Pull the safety wire 2 through the attachment point and around the truss 6 1 Clamps 2 Safety wire 3 Omega holder 4 Quick lock fastener 5 Attachment point 6 Truss Alternativelly fixtures handels can be used for safety attachment Wheninstallingfixturesside by side avoid illuminating one fixture with another DANGERTOLIFE Before taking into operation for the first time th...

Page 13: ...connected 5 Not connected If you are using the standard DMX controllers you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR out puts you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next...

Page 14: ...Blank 230 239 Lamp off by controller 240 255 Blank 7 5 Color Wheel Rata continuous positioning 0 8 White 9 17 Deep Red 18 26 Deep Blue 27 36 Yellow 37 45 Green 46 54 Magenta 55 63 Azure 64 72 Red 73 81 Deep Green 82 90 Amber 91 100 Blue 101 109 Orange 110 118 Cooling 119 127 Fluorescent Blue 128 129 White Positioning by color 130 134 Crimson 135 138 Deep Blue 139 143 Yellow 144 147 Green 148 152 M...

Page 15: ...cer 2 76 87 Beam reducer 3 Shaking gobos from slow to fast 88 95 Gobo 1 96 103 Gobo 2 104 111 Gobo 3 112 119 Gobo 4 120 127 Gobo 5 128 135 Gobo 6 136 143 Gobo 7 144 151 Gobo 8 152 159 Gobo 9 160 167 Gobo 10 168 175 Beam reducer 1 176 183 Beam reducer 2 184 199 Beam reducer 3 200 201 Blank 202 221 Forwards fixed gobo wheel rotation from fast to slow 222 223 Water stop 224 243 Backwards fixed gobo w...

Page 16: ...1 138 145 Gobo 2 146 153 Gobo 3 154 161 Gobo 4 162 169 Gobo 5 170 177 Gobo 6 178 185 Gobo 7 186 193 Gobo 8 194 199 Gobo 9 200 201 Blank 202 221 Forward rotation from fast to slow flowing water 222 223 Rotation stop 224 243 Reverse rotation from slow to fast flowing water 244 249 Random Rotation gobo selection by sound control 250 255 Random Rotation gobo selection by audio control 12 9 Gobo Rotati...

Page 17: ...sm rotation 0 127 Index 128 191 Clockwise from fast to slow flowing water 192 193 Blank 194 255 Counterclockwise from slow to fast flowing water 16 12 Frost 0 64 Blank 65 255 Frost from 0 to 100 17 13 Zoom 0 255 Zoom from max to min beam angle 18 0 255 Fine zooming 19 14 0 255 Focus 20 0 255 Fine focusing 21 0 255 Blank 22 15 Shutter Strobe 0 31 Shutter closed 32 63 Shutter open 64 95 Strobe effec...

Page 18: ...X Angle 360 540 630 XY Fback ON OFF SignalClear ON OFF Full Color ON OFF Shortcut ON OFF RST SAVE ESC ADV Zero Set Chan Def Fact Set Use Mang ESC UNLOCK PassWord1 0 255 PassWord2 0 255 KEY ESC Passport1 Zero Set Chan Def 1 Fact Set 1 Use Mang 3 MANUAL LAMP REST ALL MOTER PART MOTER XY MOTER YES NO TEST RUN AUTO SOUND ESC SMULATE DMX CH1 CH32 0 255 ESC ...

Page 19: ...obos FixeGobo Plane Titl RotGobos1 Prism Effect Prism R Effect R Zoom Focus ESC ESC DISPLAYSETTING Brightness Level 1 7 LightDelay 10Sec 20Sec 30Sec On Menuback 10Sec 20Sec 31Sec Off Flicker Off On Save ESC LAMPSETTING Default ON OFF Manual ON OFF Electronic ON OFF Back Back to last level Converse Change the display director Chinese English Change the manu language Back Back to LOGO tab DMXAddress...

Page 20: ...y glass reflector Beam range 5 20 spot application 2 5 10 beam application Colour wheel 13 dichroic filters white Static gobo wheel 10 metal gobos 4 beam reducers Rotating gobo wheel 9 glass gobos can be indexed and rotated in both directions at different speeds Gobo wheel continuous rotation Glass gobos Slot lock system for easy replacement of gobos Prisms Rotating 6 facet linear prism with conti...

Page 21: ...6 bit movement resolution Automatic Pan Tilt position correction Movement control tracking and vector Pan tilt lock mechanism Connection DMX in Out 3 pin and 5 pin XLR Power In Chassis connector PowerCon Rigging Mounting points 2 pairs of 1 4 turn locks Mounting horizontally or vertically via 2 Omega brackets Temperatures Maximum ambient temperature 45 C Maximum housing temperature 90 C Minimum di...

Page 22: ...utput but will also allow the fixture to function reliably throughout its life A soft lint free cloth moistened with any good glass cleaning fluid is recommended under no circumstances should alcohol or solvents be used Lamp driver and its heat sink is under high voltage DANGER Always disconnect the fixture from the mains before starting any maintenance work If the fixture is connected to mains hi...

Page 23: ...nt Check the air filters periodically and clean before they become clogged Clean the air filters placed in the fixture head and base Use a vacuum cleaner compressed air or you can wash them and put back dry After replacing the air filters reset the elapsed time counter in the menu Information Information Air Fil ters Elapsed Time Replacing the fuse Before replacing the fuse unplug mains lead 1 Rem...

Page 24: ...23 8 Photometric diagrams All diagrams are for full power of the lamp Standard Mode ...