Always disconnect from the mains, when the fixture isn’t in use or before cleaning it. Only handle 

the power cord by the plug. Never pull out the plug by tugging the power cord.     

During initial start-up some smoke or smell may arise. This is a normal process and doesn’t 

necessarily mean that the fixture is defective, it should decrease gradually. 

Please don’t project the beam onto combustible substances. 

If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced 

by the manufacturer or his service agent of a similar qualified person in order to avoid a hazard. 

                                  CAUTION! 

              Never touch the fixture during operation. 

              The housing may heat up. 

 

                                      CAUTION! 

  Never look directly into the light source, as sensitive persons may   

  suffer an epileptic shock.   

 

Please be aware that damages caused by manual modifications to be the fixture aren’t 

subject to warranty. Keep away from children and non-professionals. 

CLEANING AND MAINTENANCE 

1.

 

To reduce the risk of electrical shock or fire, don’t expose this unit to rain or moisture. 

2.

 

Don’t spill water or other liquids into or onto your unit. 

3.

 

During long periods of non-use, disconnect the unit’s main power. 

4.

 

It should be installed in a well-ventilated place, at a distance of 50 centimeters or more with the 

walls. At the same time, please check if the fan and ventilation holes are unobstructed. 

 

The following points have to be considered during the inspection 

1.

 

All screws for installing the lights or parts the light have to be tightly connected and must not 

be corroded. 

2.

 

There must not be any deformations on the housing. Fixations and installations spots(ceiling, 

suspension, trussing). 

3.

 

Mechanically moved parts must not show any traces of wearing and must not rotate with 

unbalances.   

4.

 

The electric power supply cables not show any damage, material fatigue or sediments. Further 

instructions depending on the installation spot and usage have to be adhered by a skilled installer 

and any safety problems have to be removed.   

                             CAUTION! 

     

Disconnect from mains before starting maintenance operation.       

 

In order to make the lights in good condition and extend the lifetime, we suggest a regular 

cleaning to the lights.   

1.

 

Clean the inside and outside lens each week to avoid the weakness of the lights due to 

accumulation of dust. 

2.

 

Clean the fan each week. 

3.

 

A detailed electric check by approved electrical engineer each three month, make sure that the 

circuit contacts are in good condition, prevent the poor contact of circuit from overheating. 

Summary of Contents for LED Spot 300W

Page 1: ...LED Spot 300W Please read this user manual before your operation ...

Page 2: ...2 1 Introduction 2 General Guideline 3 Safety Instructions 4 Cleaning and Maintenance 5 Technical Parameters 6 DMX Channels 7 Remark ...

Page 3: ... powerful and versatile fixture Unpack the fixture Inside the carton box you should find 1 1 power in cable power out connector 2 1 3pin in DMX cable 3 2 C omega clamps 4 1 safety rope 5 1 English user manual Flight case clamps are optional Please check carefully that there is no damage caused by transportation Should there be any questions please consult your dealer and don t install this fixture...

Page 4: ...c shock when touching wires This fixture has left the factory in perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual 1 In order to guarantee the product s life please don t put it in the damp places or even the environment over 60degress 2 Always ...

Page 5: ...ect the unit s main power 4 It should be installed in a well ventilated place at a distance of 50 centimeters or more with the walls At the same time please check if the fan and ventilation holes are unobstructed The following points have to be considered during the inspection 1 All screws for installing the lights or parts the light have to be tightly connected and must not be corroded 2 There mu...

Page 6: ... connection Powercon in out Cooling High efficiency die cast aluminium forced ventilation Weight Net weight 22kg Gross weight 24kg Packing Carton box packing size 50 5 49 63cm DMX CHANNELS Channel Name DMX value Function 1 Pan 0 255 Pan 2 Pine Fine 0 255 Pan Fine 3 Tilt 0 255 Tilt 4 Tile Fine 0 255 Tile Fine 5 P T Speed 0 255 P T speed 6 Dimming 0 255 Bulb Dimming 0 100 7 Strobe 0 3 Off 4 7 Open 8...

Page 7: ... 223 CW Gobo Spin fast slow 224 255 CCW Gobo Spin slow fast 11 Rotating gobo 0 11 Open 12 23 Gobo1 24 35 Gobo2 36 47 Gobo3 48 59 Gobo4 60 71 Gobo5 72 83 Gobo6 84 95 Gobo7 96 109 Gobo 7 shake slow fast 110 123 Gobo 6 shake slow fast 124 137 Gobo 5 shake slow fast 138 151 Gobo 4 shake slow fast 152 165 Gobo 3 shake slow fast 166 179 Gobo 2 shake slow fast 180 191 Gobo 1 shake slow fast 192 223 CW Go...

Page 8: ...users should be strictly comply with the warning and operating instructions as stated Or we aren t in charge of any result by misusing Any damage resulting by misuse isn t within the company s warranty Any fault or problem caused by neglecting the manual is also not in the charge of dealers Errors and omissions for every information given in this manual excepted All information is subject to chang...