background image

 

10

3.  Check the power on LED. 

 

B. Not responding to DMX controller 

1.  DMX LED should be on. If not, check DMX connectors, cables to see if link 

properly. 

2.  If the DMX LED is on and no response to the channel, check the address 

settings and DMX polarity. 

3. If you have intermittent DMX signal problems, check the pins on connectors or on   

PCB of the unit or the previous one. 

4.  Try to use another DMX controller. 

5.  Check if the DMX cables run near or run alongside to high voltage cables that 

may cause damage or interference to DMX interface circuit. 

 

C. One of the channels is not working well 

1.  The stepper motor might be damaged or the cable connected to the PCB is 

broken. 

2. 

The

 

motor’s

 

drive

 

IC

 

on

 

the

 

PCB

 

might

 

be

 

out

 

of

 

condition. 

6. Fixture Cleaning 

The cleaning of internal and external optical lenses and/or mirrors must be carried 

out periodically to optimize light output. Cleaning frequency depends on the 

environment in which the fixture operates: damp, smoky or particularly dirty 

surrounding can cause greater 

accumulation

 

of

 

dirt

 

on

 

the

 

unit’s

 

optics.

 

 

3

 

The unit is for indoor use only. Use only in a dry location. 

 

The   unit   must   be   installed   in   a   location   with   adequate   ventilation,   at   

least   50cm   from adjacent surfaces. Be sure that no ventilation slots are 

blocked. 

 

Disconnect main power before replacement or servicing. 

 

 

Make sure there are no flammable materials close to the unit while operating as 

it is fire hazard. 

 

Use safety cable when fixes this unit. DO NOT handle the unit by taking its head 

only, but always by taking its base. 

 

 

Maximum ambient temperature is Ta: 40

. DO NOT operate it where the 

temperature is higher than this Unit surface temperature may reach up to 85

DO NOT touch the housing bare-hand during  its  operation.  Turn  off  the  power 

and allow about 15 minutes for the unit to cool down before replacing or serving. 

 

 

In  the  event  of  serious  operating  problem,  stop  using  the  unit 

immediately.Never  try  to  repair  the  unit  by  yourself.  Repairs  carried  out  by 

unskilled  people  can  lead  to  damage  or  malfunction.  Please  contact  the 

nearest  authorized  technical  assistance  center.  Always  use  the  same  type 

spare parts. 

 

 

DO NOT touch any wire during operation as high voltage might be causing 

electric shock. 

 

Warning: 

 

 

To prevent or reduce the risk of electrical shock or fire, do not expose the unit to 

rain or moisture. 

 

DO NOT open the unit within five minutes after switching off. 

 

 

The    housing,    the    lenses,    or    the    ultraviolet    filter    must    be    replaced   

if    they    are    visibly damaged. 

Summary of Contents for Ostar Eye K6

Page 1: ...Ostar Eye K6 Beam and Kaleido Effects User manual Please read the instructions carefully before use ...

Page 2: ... 1 Safety Instructions Please keep this User Guide for future consultation If you sell the unit to another user be sure that they also receive this instruction booklet Unpack and check carefully there is no transportation damage before using the unit Before operating ensure that the voltage and frequency of power supply match the power requirements of the unit It s important to ground the yellow g...

Page 3: ...d in a location with adequate ventilation at least 50cm from adjacent surfaces Be sure that no ventilation slots are blocked Disconnect main power before replacement or servicing Make sure there are no flammable materials close to the unit while operating as it is fire hazard Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base Maximum ...

Page 4: ... when installing the fixture The equipment must be fixed by professionals And it must be fixed at a place where is out of the touch of people 2 Technical Specifications Light Sources 6x 15W 4in1 RGBW LED Beam Angle 6 5 Power Consumption 100W Power Voltage AC 100 240V 50 60Hz Dimension 21 19 32cm PACK 315 580 395MM 2p Net Weight 4 5Kgs Gross Weight 5Kgs Control DMX Channel 15 Channel Control Modes ...

Page 5: ...motor reset 100 255 Normal 5 Data In Out socket 3 pin 5 pin XLR sockets Power Socket Powercon in out Protection Rating IP20 Features Dimmer 0 100 smooth dimming Fast quiet operation and flicker free 3 How To Control The Unit The DMX512 is widely used in intelligent lighting control with a DMX 512 controller connect several lights together dmx in and dmx out 3 pin XLR connectors Pin 1 GND Pin 2 Neg...

Page 6: ...et Default ON OFF Re load all delivery parameter Reset Reset All Reset the light Adjust CaliT CH Password PAN TILT Password XXX PAN XXX TILT channels data calibrate code 050 PAN channel data calibrate TILT channel data calibrate DMX channel s functions and values 15 DMX channels 7 Mode Channel Value Function Standard 1 PAN Movement 8bit 0 255 Pan Movement 2 Pan Fine 16bit 0 255 Fine control of Pan...

Reviews: