ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
C406-1 (453-5002), C406-1HM (453-5003)
Page 54 of 67
Feb 28/2019
25-62-10
SUBTASK 25-62-10-450-008
I.
Airframe Ground Connections
1)
Connect the ground wires to the airframe in accordance with the aircraft manufacturer’s written
instructions or as described in AC 43.13-1, Chapter 11, § 15. See Figure 21 on page 51.
SUBTASK 25-62-10-450-009
J.
Buzzer Connection
1)
Connect the power wire to the buzzer positive (+) terminal.
2)
Connect the ground wire to the buzzer negative (
–
) terminal.
SUBTASK 25-62-10-450-010
K.
Remote Switch Final Installation
1)
Insert the harness plug into the remote switch receptacle.
2)
Install the remote switch assembly, referring to SUBTASK 25-62-10-450-002 on page 52.
TASK 25-62-10-410-802
7.
ELT Installation
SUBTASK 25-62-10-410-001
A.
Installation and Test
1)
See Figure 23.
Figure 23 ELT Installation Sequence