
PCIE Software
SharpStreamer™ Pro PCIE-7210 Installation and Use (6806800U29B
)
118
Get and Set the chassis number
Get and Set the PEX mode
List and Set SATA disk assignments to CPUs
7.6.2.1
MCCS Deployment
The configuration service is part of
pciemgmt
package. Only the
pciemgmt
together with the
RabbitMQ are started by the system on the mCPU. On other application CPUs these services
are disabled.
You can start and stop MCCS through
systemd
.
systemctl start/stop pciemgmt.service
The service writes a log file and it is available at
/var/log/mccs.log
.
The MCCS includes a pure configuration layer, which stores all configuration modifications
first. That means, all modifications will not be applied directly to the hardware. They will be
stored in the configuration layer and will be set after applying the configuration followed by
necessary reboot of the system.
At startup, the service creates the configured number of virtual functions (VF) for an Ethernet
device and creates a local MAC address for each VF. These local MAC addresses start with ‘02’.
The following bytes specify the chassis information, the address of the physical Ethernet device
(PF) and a number of the VF.
02: <chassis number LSB>:<chassis number MSB>:<slot of the PF>:<device number of the
PF>:<number of the VF>
7.6.2.2
MCCS Tool
For debug purposes, a MCCS client tool
mccs_tool.py
is available.
7.6.2.3
List device functions
To list device functions of a downstream port, use the following command.
mccs_tool.py --method=list-devices
Summary of Contents for SharpStreamer Pro PCIE-7210
Page 1: ...SharpStreamer Pro PCIE 7210 Installation and Use P N 6806800U29B January 2017...
Page 8: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 8 Contents...
Page 10: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 10 List of Tables...
Page 12: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 12 List of Figures...
Page 20: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B Safety Notes 20...
Page 24: ...SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B Sicherheitshinweise 24...
Page 30: ...Introduction SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 30...
Page 48: ...Functional Description SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 48...
Page 104: ...Base Operating System SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 104...
Page 136: ...MaxCore Firmware Upgrade SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 136...
Page 138: ...Related Documentation SharpStreamer Pro PCIE 7210 Installation and Use 6806800U29B 138...
Page 139: ......