Blade Damage
Blade Surface
Do not operate outside the specified environmental limits. Make sure the blade is
completely dry and there is no moisture on any surface before applying power.
Blade Overheating and Blade Damage
Operating the blade without forced air cooling may lead to blade overheating and thus
blade damage.
When operating the blade, make sure that forced air cooling is available in the shelf.
Table 2-1 Environmental Conditions
Characteristics
Operating
Non-Operating
Operating temperature
0°C to +55°C (32°F to 131°F) entry
air with forced-air cooling
–40°C to +85° C (-40°F to 185°F)
-40°C to +71°C (ET version)
-50°C to +100°C (ET version)
Temperature change
+/-0.5° C/min according to NEBS
Standard GR-63-CORE
Relative humidity
5% to 90% non-condensing
5% to 90% non-condensing
Vibration
1 G sine sweep, 5 - 200 Hz, with a
sweep rate of 0.25 octaves/minute
in three mutually perpendicular
axis
Summary of Contents for MVME721X RTM
Page 1: ...MVME721X RTM Installation and Use P N 6806800M42D April 2015...
Page 6: ...MVME721X RTM Installation and Use 6806800M42D 6 List of Tables...
Page 8: ...MVME721X RTM Installation and Use 6806800M42D 8 List of Figures...
Page 16: ...MVME721X RTM Installation and Use 6806800M42D Safety Notes 16...
Page 38: ...Hardware Preparation and Installation MVME721X RTM Installation and Use 6806800M42D 38...
Page 50: ...Controls LEDs and Connectors MVME721X RTM Installation and Use 6806800M42D 50...
Page 52: ...Related Documentation MVME721X RTM Installation and Use 6806800M42D 52...
Page 53: ......