During the safety qualification of this blade, the following on-board locations were identified
as critical with regards to the maximum temperature during blade operation. To guarantee
proper blade operation and to ensure safety, you have to make sure that the temperatures at
the locations specified in the
are not exceeded. If not stated otherwise, the
temperatures should be measured by placing a sensor exactly at the given locations.
Exact locations of critical temperature spots:
1. On the PIM (U34) (On top of the transformer). Maximum up to 90
o
C.
2. On the 48V/12V DC/DC (U35) (on the PCB, next to the transformer). Maximum up to
125
o
C.
Figure 2-1
Location of Critical Temperature Spots (Blade Top Side)
Temperature Spot 2
(48 V to 12 V DC DC)
Temperature Spot 1
PIM
Summary of Contents for ATCA-7480
Page 1: ...ATCA 7480 Installation and Use P N 6806800T17A February 2015...
Page 24: ...ATCA 7480 Installation and Use 6806800T17A About this Manual 24 About this Manual...
Page 30: ...ATCA 7480 Installation and Use 6806800T17A Safety Notes 30...
Page 36: ...ATCA 7480 Installation and Use 6806800T17A Sicherheitshinweise 36...
Page 42: ...Introduction ATCA 7480 Installation and Use 6806800T17A 42...
Page 64: ...Hardware Preparation and Installation ATCA 7480 Installation and Use 6806800T17A 64...
Page 82: ...Controls Indicators and Connectors ATCA 7480 Installation and Use 6806800T17A 82...
Page 98: ...Functional Description ATCA 7480 Installation and Use 6806800T17A 98...
Page 222: ...BIOS ATCA 7480 Installation and Use 6806800T17A 222...
Page 326: ...Replacing the Battery ATCA 7480 Installation and Use 6806800T17A 326...
Page 329: ......