ELECTRICAL REQUIREMENTS AND
INSTALLATION
The following information is provided for hooking up electrical supply to
your new spa. A qualified, licensed, electrician must perform this work.
Failure to follow these instructions will terminate all warranty coverage
and can cause serious injury or death.
Your spa is preset at the factory to run on 240V 60Hz with a 48A input.
This feature gives you the most performance out of your spa. This will
require a 240V, 60-amp Class A GFCI protected service.
Codes and Compliance
All of the electrical wiring methods and materials used to complete the
electrical installation of the control system must be in accordance with
the National Electrical Code or the Canadian Electric Code, as well as
any local electrical codes in effect at the time of installation.
The selection of electrical materials required to accomplish this installa-
tion and the installation of the control system must be accomplished by,
or be under the direct supervision of, a qualified electrician.
The control is classified as a “continuous duty appliance” and is intend
-
ed primarily for installation at a single family dwelling. The installation
recommendations and instructions contained in this manual are directed
solely toward these issues.
GFCI Requirements
A Ground-Fault Circuit Interrupter (GFCI) is required to be installed in
the electrical supply circuit connected to these products.
6
North American 60 Hz
240V/40A*
240V/50A**
240V60A***
Voltage 240VAC 240VAC 240VAC
Max Current Draw 32A 40A 48A
Number of Wires 4 4 4
Circuit Breaker 40A* 50A** 60A***
* In this configuration, the heater will not operate while either jets pump is running
or when the blower is running.
** In this configuration, the heater will not operate while both jet pumps are running.
***
In this configuration the heater will operate while both jets pumps and the blower
are running.