SPA START-UP
FILLING THE SPA WITH WATER
5) Once the water level is filled over the foot-well, you can pull the hose
out of the filter line and continue filling the spa from the filter well.
6) Fill the spa to the bottom of the pillows.
NOTE: DO NOT OVER-FILL YOUR TUB!
7) With the front panel off, verify there are no leaks at the pump union.
NOTE: Pump unions can become loose during shipping. Verify that
there are no leaks during filling of the spa.
8) Reinstall the filters.
TURNING THE POWER ON
Turn the power to the spa on at the main circuit breaker. Verify that your
spa has no messages. Verify that there is good water circulation in the
spa. The pumps will come on in cycles, for 1 minute each cycle.
TESTING THE GFCI BREAKER
NOTE: The electrical service panel for your spa should be equipped
with a GFCI breaker. To avoid the risk of electrical shock, perform the
following safety test before each use of your spa.
1) Make sure the power is turned on at the electrical service panel.
2) Turn on the GFCI breaker. If the breaker stays on, it is functioning prop-
erly.
NOTE: The spa system will automatically trip the GFCI 24 hours after
power up. This is a safety feature and can not be disabled.
VERIFYING WATER CIRCULATION
1) Open all the jets.
2) Press the Pump 1 key to turn the pumps on or off.
3) Make sure each seat has water flow. Note: On certain spas there is
a diverter valve. Verify where the diverter valve is located.
14