Page 7
Fiberlink® 7600 Series User’s Manual
Fiberlink® 7600 Series
The Fiberlink® 7600 Series of fiber optic transmission system is ready for
immediate use and does not require any special tools or equipment. However, an Optical
Power Meter, such as the Fiberlink® 6650, can be useful in determining optical loss budgets
during your system’s design and system maintenance.
The following instructions describe the typical installation procedure:
1) Connect the HDMI® video source to the video input HDMI® connector on the
transmitter unit.
2) Determine your EDID requirements and follow the procedures described in the
“EDID Function” section of this manual.
3) Connect the video output on the receiver unit to the HDMI® monitor or load.
4) Connect the fiber optic cable between the two Fiberlink units.
5) Apply power to both the Fiberlink units.
For box versions using DC power connections, refer to Figure 1.
6) When power is applied, the green POWER LED will light, indicating the presence
of operating power. The VIDEO LED will give an indication as described on page 13.
The green AUDIO LED will give an indication as stated on page 13.
7) The system should now be operational.
Note: The transmitter and receiver will each perform HDCP authentication with their source and
load. This will take several seconds to accomplish proper authentication.
Note: The Rack Card version has an additional red LED for indicating the presence of an alarm
condition (loss of signal). Refer to Indicator LED’s and Alarm Switch Settings & Options sections
of this manual.
Installation Instructions
The transmitting element in the Fiberlink® 7600 transmitter
unit contains a solid state Laser Diode located in the optical
connector. This device emits invisible infrared electromag-
netic radiation which can be harmful to human eyes. The ra-
diation from this optical connector, if viewed at close range
with no fiber optic cable connected to the optical connector,
may be sufficient intensity to cause instantaneous dam-
age to the retina of the eye. Direct viewing of this radiation
should be avoided at all times!
Installation Instructions