background image

WWW.ARTEL.COM

MANUAL

One-Way 3G/HD/SD-SDI 

Transmission  with two way audio, 

data, 10/100 Ethernet & contact 

closure over one or two fibers
Installation and Operations  

Manual

FiberLink 

3390 Series

Summary of Contents for FiberLink 3390 Series

Page 1: ...WWW ARTEL COM MANUAL One Way 3G HD SD SDI Transmission with two way audio data 10 100 Ethernet contact closure over one or two fibers Installation and Operations Manual FiberLink 3390 Series...

Page 2: ...Output Switch Settings For Box Versions 11 Data Configuration For Box Versions 11 Ethernet Configurations For Box Versions 12 Baud Rate Configuration For Box Versions 12 Data Wiring For Box Versions 1...

Page 3: ...io two each way Transmit and Receive 1 channel of RS Type data Transmit and Receive 10 100 Base T Ethernet Transmit and Receive 1 channel of contact closure All channels are independent and available...

Page 4: ...te each by replacing z with L or S Data Specifications General Specifications Model Part Number Specification Technical Specifications Data Channels 1 Channel Bi Directional Data Bandwidth DC to 115 K...

Page 5: ...quency Response 0 0 5 dB 20 Hz 20 kHz Maximum Audio Level 10 dBu Signal to Noise Ratio A weighted 95 dB referenced full scale balanced THD 0 002 20Hz 20 kHz full scale Channel Phase Differential 0 1 C...

Page 6: ...ications Number of Inputs 1 Data Bandwidth 19 4 Mbps to 2 97 Gbps Supported Standards SMPTE 259M 292 424M 2006 305M 344M DVB ASI Reclocked Data Rates 270 Mbps SMPTE 259M DVB ASI 270 1 485 Gbps SMPTE 2...

Page 7: ...SMPTE 292 0 4 ns to 1 5 ns at 270 Mbps per SMPTE 259M Overshoot 10 of amplitude Timing Jitter 0 2 UI at 270 Mbps 1 0 UI at 1 485 Gbps 2 0 UI at 2 97 Gbps with color bar signal Alignment Jitter 0 2 UI...

Page 8: ...Fiberlink devices Operating loss budget must not be exceeded Operating Loss Budget Maximum Useable Distance The FiberLink 3390 Series of fiber optic transmission systems are ready for immediate use a...

Page 9: ...or LED s and Alarm Circuitry section of this manual 11 The system should now be operational Note The Rack Card version has an additional red LED for indicating the presence of an alarm condition loss...

Page 10: ...t Channel 2 Input 1 2 1 2 G Ground Shield Channel 1 Input Channel 2 Input Balanced Channel 1 Signal Channel 2 Signal Shield Channel 1 Ground Channel 2 Ground Un Balanced Channel 1 Output Channel 2 Out...

Page 11: ...Channel Balanced Unbalanced Channel 1 controlled by Switch 2 Channel 2 controlled by Switch 1 Audio Output Switch Settings For Box Versions Data Configuration For Box Versions The Fiberlink 3390 Seri...

Page 12: ...5 6 7 8 9 19 2k E 1 2 3 4 5 6 7 8 9 38 4k E 1 2 3 4 5 6 7 8 9 57 6k E 1 2 3 4 5 6 7 8 9 76 8k E 1 2 3 4 5 6 7 8 9 4800 E 1 2 3 4 5 6 7 8 9 9600 Ethernet Configurations For Box Versions DATA CONFIG E 1...

Page 13: ...9 RS 422 485 4 Wire RS 485 2 Wire RS 232 Data Wiring For Box Versions RS 485 2 Wire RS 232 G 1 2 3 4 Input G 1 2 3 4 Output RS 422 485 4 Wire G 1 2 3 4 Input G 1 2 3 4 Output G 1 2 3 4 Input Output Co...

Page 14: ...nel Balanced Balanced Unbalanced 600 Ohms 24k Ohms 24k Ohms 1 2 3 4 Channel 1 controlled by Switches 1 2 1 2 3 4 1 2 3 4 1 2 3 4 Channel 2 controlled by Switches 3 4 Audio Input Switch Settings For Ca...

Page 15: ...h Settings For Card Version The Fiberlink 3390 Series card units have three switch blocks one 10 position one 4 posi tion and one 2 position The first block Data Config represents the Ethernet and RS...

Page 16: ...2 485 4 Wire 1 2 3 4 5 6 7 8 9 10 RS 485 2 Wire 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 RS 232 2400 1 2 3 4 5 6 7 8 9 10 DATA CONFIG 4800 1 2 3 4 5 6 7 8 9 10 DATA CONFIG 9600 1 2 3 4 5 6 7 8 9 10 D...

Page 17: ...RS 485 2 Wire Contact Closure Wiring For Card Versions Ethernet Configurations For Card Version 10 Base T Ethernet 100 Base T Ethernet G 1 2 3 4 G 1 2 3 4 RS 232 Input Output G 1 2 3 4 G 1 2 3 4 RS 42...

Page 18: ...output to drive a model 6020A Alarm Sensing Module which provides an audible tone and activates a set of contacts for external signaling purposes Alarm Switch Settings Options Alarm Switch Settings C...

Page 19: ...l On Indicates HD 3G SDI data rate lock at 1 485 Gbps or 2 97 Gbps SD TX Off Indicates no SD SDI data rate lock electrical On Indicates SD SDI data rate lock at 270 Mbps SD RX Off Indicates no SD SDI...

Page 20: ...ould provide the first clue as to the origin of any operational failure If these are off it usually means that the fiber is broken or has too much attenuation Next be certain that the input and output...

Page 21: ...transmission and that electrical connections are secure and accurate Please see the Troubleshooting section of this manual for additional information An optical power meter such as the FiberLink 6650...

Page 22: ...convenient on site testing of fiber networks during construction and maintenance procedures FiberLink 6650 Optical Power Meter The Fiberlink 6650 Optical Power Meter is a high accuracy high resolution...

Page 23: ...Page 23 FiberLink 3390 Series User s Manual FiberLink 3390 Series...

Page 24: ...tured in the USA Training and installation support available 24x7x365 technical support available Proven Products Unrivaled Service and Great Support Artel Video Systems Corp 5B Lyberty Way Westford M...

Reviews: