![Artel 3334-F9 Installation And Operation Manual Download Page 6](http://html1.mh-extra.com/html/artel/3334-f9/3334-f9_installation-and-operation-manual_2977503006.webp)
Page 6
Fib
FiberLink 3334 Series User’s Manual
FiberLink 3334 Series
Installation Instructions
The FiberLink 3334 Series of fiber optic transmission systems are ready for
immediate use and do not require any special tools or equipment . However, an Optical
Power Meter, such as the FiberLink 6615, can be useful in determining optical loss budgets
during your systems design and maintenance .
The following instructions describe the typical installation procedure:
1) Connect the video source(s) to the video input(s) on the transmitter unit .
2) Connect your video output cable(s) to the video output connector(s) on the
receiver unit .
3) Connect the fiber optic cable to the transmitter and receiver units .
4) Connect the power cables to the transmitter and receiver units .
5) When power is applied, the green POWER LED should illuminate, indicating the
presence of operating power . The Video LEDs will give an indication
as described in the Indicator LED’s and Alarm Circuitry section of this manual .
Installation Instructions
The transmitting element in the FiberLink 3334 transmitter
unit contains a solid state Laser Diode located in the optical
connector. This device emits invisible infrared electromagnetic
radiation which can be harmful to human eyes. The radiation
from this optical connector, if viewed at close range with no
fiber optic cable connected to the optical connector, may be
sufficient intensity to cause instantaneous damage to the
retina of the eye. Direct viewing of this radiation should be
avoided at all times!
CAUTION: RISK OF ELECTRICAL SHOCK
To reduce the risk of electrical shock, do not remove the
cover. No user serviceable parts inside. Refer servicing to
qualified service personnel.