![Artecta ECOdrive DC15W Product Sheet Download Page 3](http://html1.mh-extra.com/html/artecta/ecodrive-dc15w/ecodrive-dc15w_product-sheet_2977424003.webp)
Quick Start Guide ECOdrive 15
Manual configuration
1. Select mode of operation:
2. Set LED current and LED groups:
3. Standalone operation
or
Standalone operation
or
Networked operation
- Colour*- - Show - - DMX mode-
* The colour menu depends
on the LED group settings you
have selected in step 2.
M
SHOW
display off
COLR
DMX
(5 sec)
M
+
-
/
Set mode
MODE
SET
1-1L
2-2L
3-3L
4-4L
OFF
POTM
10V
SWIT
2-4L
1-4L
RGB
RGBW
RGBA
RRGB
RGGB
CCWW
CWWW
display off
M
CURR
M
M
M
+
-
+
/
+
-
/
+
-
/
LED groups
Output current
LED
+
200 mA
+ 50 mA
External input
EXT INP
00...20
M
display off
SHOW
M
M
M
-99...99
0...255
+
-
/
+
-
/
+
-
/
Intensity
Speed
Show
SPD
INT
M
M
M
+
-
/
+
-
/
1...512
Network resolution
DMX address
8 BT
16 BT
display off
ADDR
DMX
RES
NETW
M
HUE
M
HUE
White
WHIT
M
M
+
-
/
Intensity
0...255
INT
display off
+
-
/
0...1535
+
-
/
0...255
Other features
Visual test run of connected LEDs
Locking the configuration:
Reset to factory defaults
M
display off
TEST
-
+
Test
+
+
R 1 sec
G 1 sec
B 1 sec
W 1 sec
RGBW 1 sec
R 1 sec
G 1 sec
B 1 sec
W 1 sec
RGBW 1 sec
+
-
/
display off
M
LOCK
M
+
Lock driver
(5 sec)
+
NO
SOFT
HARD
M
display off
RE - SET
-
+
Reset
+
+
(5 sec)
M
Press menu
PRES MENU
Constant current LED Driver