background image

 

 

 

42 

 

  

 

 

Image Spot 100 

Product code: A0690100 

 

 

Summary of Contents for 602207

Page 1: ...Image Spot 100 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Product code A0690100 USER MANUAL ENGLISH V1...

Page 2: ...evice Non observance of the instructions in this user manual may result in serious injuries and damage of property 2022 Artecta All rights reserved No part of this document may be copied published or...

Page 3: ...n 13 Personal Protective Equipment 13 Installation Site Requirements 13 Rigging 14 Angle Adjustment 16 Free standing Bracket Installation 17 Connecting to Power Supply 17 Power Linking of Multiple Dev...

Page 4: ...Information 37 RDM Details 37 Supported RDM PIDs Parameter IDs 37 7 Troubleshooting 38 8 Maintenance 39 Safety Instructions for Maintenance 39 Preventive Maintenance 39 Basic Cleaning Instructions 39...

Page 5: ...n intended and incorrect use Product Lifespan This device is not designed for permanent operation Disconnect the device from the electrical power supply when the device is not in operation This will r...

Page 6: ...if not avoided may result in minor or moderate injury Attention Indicates important information for the correct operation and use of the product Important Read and observe the instructions in this doc...

Page 7: ...service and maintenance and when the device is not in use DANGER Electric shock caused by short circuit This device falls under IEC protection class I Make sure that the device is electrically connect...

Page 8: ...paired for example by cracks or deep scratches Contact your Highlite International dealer for more information as servicing can be performed only by instructed or skilled persons If the device is drop...

Page 9: ...enance may be carried by ordinary persons Installation and service shall be carried out only by instructed or skilled persons Contact your Highlite dealer for more information Instructed persons have...

Page 10: ...be recalled A 3 facet rotational prism enables you to create dynamic effects In addition a ripple effect can be engaged to imitate waving flag patterns and create an additional dimension to the projec...

Page 11: ...Spot 100 Product code A0690100 Back View Fig 03 04 3 pin IP65 DMX signal connector IN 05 IP65 power IN 06 LED Display Menu Buttons 07 Protective Vent 08 IP65 power OUT 09 3 pin IP65 DMX signal connec...

Page 12: ...and control Control Stand alone auto manual Master Slave auto manual DMX 512 RDM DMX channels 13 channels Control panel LED display Connections Power connections Dedicated IP65 Power connectors IN OUT...

Page 13: ...Cable 1 5m Product code A9920801 IP 67 Data Extension Cable 3m Product code A9920802 IP 67 Data Extension Cable 6m Product code A9920803 IP 67 Data Extension Cable 1 5m Product code A9920820 IP 67 Po...

Page 14: ...ve Equipment During installation and rigging wear personal protective equipment in compliance with the national and site specific regulations Installation Site Requirements The device can be used outd...

Page 15: ...tioned on a flat surface or mounted to a truss or other rigging structure in any orientation Make sure that all loads are within the pre determined limits of the supporting structure Fig 05 CAUTION Re...

Page 16: ...device cannot move freely 02 Secure the device with a secondary suspension for example a safety cable Make sure that the secondary suspension can hold 10 times the weight of the device If possible th...

Page 17: ...with the adjustment screw 03 01 Turn the adjustment screw 03 counterclockwise to release it 02 Tilt the device to the desired angle see Fig 07 03 Turn the adjustment screw 03 clockwise to tighten it...

Page 18: ...supply matches the input voltage specified on the information label on the device Make sure that the socket outlet has ground earth connection Connect the device to the socket outlet with the power p...

Page 19: ...cal circuit and result in serious injuries and damage of property To prevent overload of the electrical circuit when power linking multiple devices Use cables with sufficient current carrying capacity...

Page 20: ...shows of two or more devices set in a master slave operating mode The Image Spot 100 has 3 pin DMX signal IN and OUT connectors The pin assignment is as follows 3 pin pin 1 ground pin 2 pin 3 Devices...

Page 21: ...in Fig 09 Fig 09 Master Slave Setup The Image Spot 100 supports master slave control mode To connect multiple devices in master slave setup follow the steps below 01 Connect the first device s DMX OU...

Page 22: ...devices make sure that you set the DMX starting address of each device correctly The Image Spot 100 has 1 personality 13 channels If you want to connect multiple devices on one data link and use them...

Page 23: ...100 supports the following control modes Stand alone Auto manual Master Slave Auto manual DMX 512 13 channels For more information about how to connect the devices refer to 5 Setup on pages 19 21 To...

Page 24: ...up the display will show a splash screen with the name and current software version of this device Immediately afterwards the display will show the start screen The start screen provides information...

Page 25: ...24 Image Spot 100 Product code A0690100 Menu Overview...

Page 26: ...25 Image Spot 100 Product code A0690100...

Page 27: ...3 5 DMX Addressing on page 21 for more information 02 Confirm your choice with the SET button Auto Mode In this menu you can select the auto program or edit a scene 01 While in the main menu press the...

Page 28: ...he slave mode of the device 01 Once you have selected Slave Mode the device will operate as a slave device in master slave mode This means that it will react the same as the master device Manual Mode...

Page 29: ...can adjust the device s settings 01 Press the UP DOWN buttons to select a parameter There are 7 options available DIMMER CURVE DMX FAIL DISPLAY KEY LOCK BACK LIGHT RESET DEFAULT 02 If you have select...

Page 30: ...ss the UP DOWN buttons to choose the desired dimming curve out of the 4 available options 04 Press the SET button to confirm your choice DMX Fail With this menu you can set the device s behavior in ca...

Page 31: ...one of the 2 options LOCK after 30s The device will lock after 30 seconds To light up the display you have to press the MODE and SET buttons for 3 seconds Once you have pressed these 2 buttons the di...

Page 32: ...SET button the device will reset its gobo wheel 02 Press the SET button to confirm your choice Default With this menu you can restore the default factory settings 01 Press the UP DOWN buttons to selec...

Page 33: ...lue The adjustment range is 000 255 05 Confirm your choice with the SET button 06 Press the UP DOWN buttons to select another parameter you want to change Information In this menu you can view the cur...

Page 34: ...000 255 Color wheel positioning fine tuning 5 Gobo 000 008 Gobo 1 White circle 009 017 Gobo 2 Ice Stars 018 026 Gobo 3 Merry Christmas 027 035 Gobo 4 Sale 036 044 Gobo 5 Coffee Tea Food 045 053 Gobo...

Page 35: ...ouch voltage may be present Disconnect the device from electrical power supply before service and maintenance and when the device is not in use Allow the device to cool down before opening the cover U...

Page 36: ...ently lift the gobo holder a bit up and pull it out from the rotating gobo wheel as shown in Fig 15 and Fig 16 Fig 15 Fig 16 Very carefully remove the retainer spring from the gobo holder with a small...

Page 37: ...ed with the coating against the rim of the holder away from the spring Textured gobos are inserted with the smooth side against the spring This provides the best results when combining rotating gobos...

Page 38: ...lue Required GET SET DISC_UNIQUE_BRANCH 0x0001 DISC_MUTE 0x0002 DISC_UN_MUTE 0x0003 SUPPORTED_PARAMETERS 0x0050 PARAMETER_DESCRIPTION 0x0051 DEVICE_INFO 0x0060 DEVICE_MODEL_DESCRIPTION 0x0080 MANUFACT...

Page 39: ...3 pin 5 pin DMX OUT of the controller does not match the DMX IN of the device Install a phase reversing cable between the controller and the device The controller is defective Try using another contr...

Page 40: ...n the conditions at the site where the device is installed When smoke or fog machines are used at the site the device will need more frequent cleaning On the other hand if the device is installed in w...

Page 41: ...ts inside the device follow the steps below to remove the condensation water 01 Carefully remove the protective vents 7 with a wrench 16 mm Fig 19 Let the device operate at full output for 60 minutes...

Page 42: ...is side up Fragile Storage Clean the device before storing Follow the cleaning instructions in chapter 8 2 1 Basic Cleaning Instructions on page 39 Store the device in the original packaging if possib...

Page 43: ...42 Image Spot 100 Product code A0690100...

Page 44: ...2022 Artecta...

Reviews: