![ArSilicii AL320 Series Manual Download Page 10](http://html1.mh-extra.com/html/arsilicii/al320-series/al320-series_manual_2976879010.webp)
ArSilicii v041113
10
FRESH2:
X
%
This item of the menu shows the level of the additional fresh water tank expressed in percentage of
the total volume. (for a probe with 4 levels (0%-30%-60%-90%)
DRAIN 1: NO/FULL
Indicates whether the drain recovery tank 1 is full or not.
DRAIN 2: NO/FULL
Indicates whether the drain recovery tank 2 is full or not.
GAS-SOLENOID VALVE
Functions that can be activated only by the installation of optional kit.
This contains the items of the menus related with the protections against gas leaks and the presence
of carbon dioxide and it indicates the status of the gas solenoid valve.
GAS SENS: ON/OFF/GAS/--
The dashes (--) indicate that the sensor is not installed or is not working properly. The word ON
flashing means that the sensor is warming up, and is therefore unable to detect an alarm situation.
The word ON stops flashing when warm-up has been completed.
The word GAS appears when an alarm situation has occurred, i.e. there is a gas leak.
ALR BUZZ: ON/OFF/--
The dashes (--) indicate that the sensor is not installed or is not working properly. The ON control
enables the buzzer on the sensor to sound in the case of alarm, while the OFF one disables it.
BATTERIES
This contains the items of the menus related with the measurements of the voltage rates on the two
batteries (engine and services), of the current delivered and of the charge quantity stored.
The bars indicate that the services battery is starting to get damaged.
SERV BATT :
X
V
Indicates the voltage, expressed in Volts, at the terminals of the services battery.
ENG BATT:
X
V
Indicates the voltage, expressed in Volts, at the terminals of the engine battery.