Page 5
P28E
1E
Daylight Saving Start Month -
Value 1-12 - Default = 9
2E
Daylight Saving End Month -
Value 1-12 - Default = 4
P29E
1E
Daylight Saving Start Hour -
Value 0-23 - Default = 2
2E
Daylight Saving End Hour -
Value 0-23 - Default = 3
+++++
O
u
t
pu
t
s+++++
Programming Output Options “A”
P34E
1-8E
Options “A” for Outputs 1-8
1 = Invert Output
(Default = All Off)
2 = Flash Output
3 = Single Pulse to Output
4 = Lockout Output
5 = DTMF Remote Control can operate Output
6 = User Can operate this Output
7 = “Control” button Can Operate Output
8 = Chime Alarms will Flash this Output (linked to Pulse Timer)
Programming Output Options “B”
P35E
1-8E
Options “B” for Outputs 1-8
1 = Mains Fail to Output (Operates when P25E6E time expires)
(Default O/P’s 1&2 = 7)
2 = Fuse Failure to Output
(Default O/P’s 3-8 = All Off)
3 = Battery Low to output
4 = Telephone Line Failure to Output
5 = Supervised Radio Signal Failure
6 = Sensor-Watch Alarm
7 = System Tamper to Output
8 = Receiver Fail
Programming Output Options “C”
P36E
1-8E
Options “C” for Outputs 1-8
1 = Walk Test Pulse to Output
(Default = All Off)
2 = Pulse Output every 5 seconds when Disarmed
3 = Pulse Output on Kiss-off Following Arming
4 = Pulse Output on Kiss-off Following a Zone Alarm
5 = Output Disabled when P25E3E timer is running
6 = Spare
7 = Spare
8 = Spare
Programming Output Options “D”
P37E
1-8E
Options “D” for Outputs 1-8
1 = Siren Driver to Output (requires a horn speaker, outputs 1&2)
(Default = All Off)
2 = Output Reset-Chime timers are in minutes (off for seconds-1/10th secs)
3 = Output ‘silenced’ for 10 seconds on key-press if alarm
4 = Turn Output OFF during Two Way Voice Mode
5 = Spare
6 = Spare
7 = Spare
8 = Monitored Output (can tell if siren cable is cut, outputs 1&2 only)
Output ON Delay Time
P38E
1-8E
Output 1-8 ON Delay Time -
0-9999 Seconds (Default = 0 Sec)
Output Pulse Time
P39E
1-8E
Output 1-8 Pulse Time -
0-255;1/10th Sec increments (Default =2 which is 0.2 sec)
Output Reset Time
P40E
1-8E
Output 1-8 Reset Time -
0-9999 Seconds (Default = 300 Sec)
(if option 2 at P37E is on the reset time is in minutes)
Output Chime Mode Time
P41E
1-8E
Output 1-8 Chime Timer -
0-255;1/10th Sec increments (Default =10 which is 1 sec)
Start of Output “Command Control” Status Messages
P42E
1-8E
Start message Number for Outputs 1-8 “Command Control” -
0-99 (Default = 0)
Un-Map an Output
P43E
1-8E
Un-map Outputs 1-8 (remove ALL Defaults from an Output)
Assigning a Time-zone to an Output
P44E
1-8E
Time-zones that will control Outputs 1-8
-
Value = Time-zone 1-8 (Default = All Off)