Instruction Manual of PR5534-01 Model Controller
2010-12-01 N0
:
VER1.1
-
4
-
5.1
When the system is on, press “
” or “
” to move the cursor to “Steam” ,
press “
” to turn on the steam generator, steam icon on LCD blinks; water
intake valve opens automatically and water come into the steam generator.
5.1.1 If the water level sensor checks the water level achieves the setting value,
the water input stops and the steaming function starts. The controller
commands the inner temperature according to the defaults (Inner
temperature is 45
℃
, time default is 45 minutes). It supplies water if
needed.
Control rule:
Inner temperature>Default temp1
℃
; The steam generator stops heating.
Inner temperature<Default temperature-1
℃
, The steam generator reheats.
5.1.2 When run out of the work time, steam function stopped automatically.
5.2
Press “
” again to turn off the steam function, steam icon stops blink.
5.3
Temperature setting
5.3.1 When the steam function is on
,
press “
” continually till temperature on
LCD blinks, then press“
” to increase the temperature, press “
” to
decrease the temperature.
5.3.2 Temperature setting scope
:
25
℃
--60
℃
5.4
Time setting
5.4.1 When the steam function is on
,
press “
” continually till time on LCD
blinks
,
then press “
” to increase the time
,
press “
” to decrease the
time.
5.4.2 Time setting scope
:
10—60minutes.
6
FM digital turning radio
6.1
The FM frequency scope is 87.5MHz—108.0MHz.
6.2
When the system is on
,
press “
” or “
” to move the cursor to “Music”
,
press “
” to turn on the FM radio, “FM” will display on LCD
;
press “
”