O W N E R S M A N U A L
Form: F- 0071
MINI-REGENERATIVE AIR DRYER
power
MODELS RH105 THROUGH RH125
Mini-Regenerative
Air Dryer
ARROW PNEUMATICS
Page 1: ...O W N E R S M A N U A L Form F 0071 MINI REGENERATIVE AIR DRYER power MODELS RH105 THROUGH RH125 Mini Regenerative Mini Regenerative Air Dryer Air Dryer ARROW PNEUMATICS...
Page 2: ...URE 75 PSIG MAXIMUM INLET TEMPERATURE 120 F MINIMUM INLET TEMPERATURE 32 F STANDARD 40 F PRESSURE DEW POINT OPTIONAL 100 PRESSURE DEW POINT STANDARD CYCLE TIME 5 MINUTES OPTIONAL CYCLE TIME 2 MINUTES...
Page 3: ...conditions Best results occur when dryer is located as close to point of use as practical Avoid locating dryer outside or where it is exposed to the elements Dryers are sized according to airflow not...
Page 4: ...side of cabinet After filters located after the dryer help eliminate the possibility of desiccant dusting and carry over into the air system Install Purge Muffler shipped separately inside of cabinet...
Page 5: ...eaks detected must be fixed especially those on the outlet side of the dryer Energize electrical circuit by simply pressing the on off switch to the ON position The switch indicator light will be illu...
Page 6: ...alve redirects flow repeating the cycle These cycles are reduced to two minute cycles if the 100 F dew point is selected Required purge air is generally 15 of rated flow All Arrow Pneumatic Mini Regen...
Page 7: ...126065 126065 126065 MUFFLER SQF 3 SQF 3 SQF 3 SQF 3 SQF 3 ON OFF SWITCH 57300 57300 57300 57300 57300 5 MINUTE TIMER 120V 126707 126707 126707 126707 126707 5 MINUTE TIMER 220V 126750 126750 126750 1...
Page 8: ...buse or accident This warranty will apply to equipment installed operated and maintained in accordance with the procedures and recommendations as outlined in the owners manual published by Arrow Pneum...