0709

EQUIPOTENTIAL 

The appliance must be connected to an equipotential system . 

The connection screw is located on the rear part of the appliance and marked by the symbol: 

                      

 

 

 

 

 

 

 

 

 

 

Caution: the manufacturer is not liable and is not required to compensate under the guarantee for damage caused by 

inadequate installation and failure to follow the installation instructions.    

STARTING UP

Before using the appliance for the first time it must be carefully cleaned, see paragraph “Cleaning and Maintenance” . 

Check the connection of the appliance and start it following the instructions .

INSTRUCTIONS FOR USE

Caution: the appliance should not be left operating unmanned.

Remember that the grill surface becomes very hot during use .

GRILLvAPOR® appliances are designed for grilling meat, fish, vegetables, cheese etc . 

SWITCH-ON

Check that the water tray is inserted . Fill the tray with water . In the 910EL series it is filled by opening the chromium-plated water 

tap with blue band (fig . 7) . 

Check that the grill surface is fully lowered and resting horizontally on the Grillvapor body . 

Turn on the switch upstream of the appliance . 

In model GV819EL it is possible to operate the grill surface in two parts at separate temperatures . 

The green light indicates that the appliance is powered . 

To switch the appliance on, turn the yellow knob from position “0” to “MAX” . 

The yellow/orange light indicates operation of the heating element; when it goes out it means that the temperature has been 

reached . In the “MAX” position the yellow/orange light remains on continuously . 

To switch the appliance off, set the yellow knob to “0” .

SPECIAL INSTRUCTIONS

During use of the Grillvapor you are advised to use a steel brush to clean the grill surface . 

To avoid overheating, unnecessary smoke and danger of the oil in the collecting pan catching fire, always cook with the tray 

below the grill surface full of water, keeping an eye on the level during cooking (fig. 4 and fig.6).

CLEANING AND MAINTENANCE

Caution: during cleaning do not wash the outside of the appliance with direct or high pressure jets of water.

Caution: during cleaning do not wash the outside of the appliance with direct or high pressure jets of water . 

Thoroughly clean the appliance every evening after work . Daily cleaning will ensure perfect operation and long life of the grill . 

Disconnect the appliance before beginning cleaning . The steel parts should be washed with hot water and neutral detergent, 

thoroughly rinsed to eliminate all traces of detergent and then dried with a dry cloth . 

Do not use abrasive or corrosive detergents.

Cleaning of the parts in contact with the food is simple: the ventilation element end cover and front panel can be pulled out 

easily and the grill surface can be raised 60° to facilitate access to the lower part - a handle with catch is provided to facilitate 

raising of the grill surface and the support inside the appliance on the right props the grill surface open (fig . 2) . The water tray 

can be pulled out to facilitate cleaning (fig . 5) . In the 710EL and 910EL series the tray is positioned on sliding rails and can also be 

pulled out to facilitate cleaning (fig .6) . In addition, the two aforementioned series have a drain tray under the water tray which is 

also extractable for thorough cleaning (fig .7) .

Summary of Contents for GRILLVAPOR 550EL

Page 1: ...700EL 710EL 900EL 910EL Installation and operation manual E n g l i s h E L E C T R I C G R I L L EEC DIRECTIVE 73 23 93 68 89 336 ATTENTION CHARCOAL OR SIMILAR COMBUSTIBLES MUST NOT BE USED WITH THES...

Page 2: ......

Page 3: ...pag 5 Cleaning and maintenance pag 5 What to do if the grill is not being used pag 6 What to do if a fault occurs pag 6 MAINTENANCE Acces to the electrical box pag 6 Acces to the electrical resistance...

Page 4: ...ion In the event a fixed equipment does not have a power lead and plug or any other device to disconnect it from the electric board which has sufficient tripping between contacts to ensure total disco...

Page 5: ...inuously To switch the appliance off set the yellow knob to 0 Special instructions During use of the Grillvapor you are advised to use a steel brush to clean the grill surface To avoid overheating unn...

Page 6: ...stances The electrical resistances are clad in stainless steel 18 10 AISI 304 and are housed in special profile tubes If a resistance breaks ensure that the electricity supply is disconnected The elec...

Page 7: ...7 0709 Fig 01 Fig 05 Fig 03 Fig 02 Fig 06 Fig 04...

Page 8: ...0709 8 Fig 07 Fig 09 Fig 08...

Page 9: ...C B A Put the handle between the heating elements B Turn the handle of 90 towards the left C Pull up to lift the cooking surface D Fix the cooking surface with the special support D HOW RAISE THE GRIL...

Page 10: ...iate holes 2 Fix the plates to the bottom of the appliance 3 Screw in the M10 pin located at the centre of the plates 1 Place your Grillvapor on the cabinet and screw in the 4 bolts FASTENING OF THE F...

Page 11: ...3N 5x2 5 mmq H07RN F5G2 5 7 5 A GV 870EL 800X700X315 780X530 10 4 Kw 50 60Hz 230V 3 4x4 mmq H07 RN F4G4 26 1 A 400V 3N 5x2 5 mmq H07RN F5G2 5 15 A 700EL GV 407EL 420X700X440 380X530 230V 3X4 mmq H07...

Page 12: ...RVATO E PROTETTO A TERMINE DI LEGGE CON DIVIETO DI DIVULGAZIONE ANCHE PARZIALE A TERZI SENZA ESPLICITA AUTORIZZAZIONE SCRITTA 455EL 470EL 407EL 417EL APPR VERIF SCALA WIRING DIAGRAM 230 V 230V 5 Resis...

Page 13: ...TO A TERMINE DI LEGGE CON DIVIETO DI DIVULGAZIONE ANCHE PARZIALE A TERZI SENZA ESPLICITA AUTORIZZAZIONE SCRITTA 455EL 470EL 407EL 417EL 409EL 419EL APPR VERIF SCALA WIRING DIAGRAM 230 V 3 230V 3 4 S 4...

Page 14: ...A TERMINE DI LEGGE CON DIVIETO DI DIVULGAZIONE ANCHE PARZIALE A TERZI SENZA ESPLICITA AUTORIZZAZIONE SCRITTA 455EL 470EL 407EL 417EL 409EL 419EL APPR VERIF SCALA WIRING DIAGRAM 400 V 3N 400V 3N 5 6 5...

Page 15: ...4 2 3 1 4 S 1 2 A2 P 1 2 P 2 S 5 A R 6 1 2 3 4 3 2 3 A 1 R 1 R 2 R 3 R 4 R 5 5 R 10 R 8 R 7 R 9 6 R 11 R 12 1 2 3 4 1 2 3 4 1 2 3 1 3 2 1 3 3 3 4 S 4 1 2 A2 P 1 2 P 2 S 5 A R 6 1 2 3 4 3 2 3 A 1 R 1 R...

Page 16: ...1 4 S 1 2 A2 P 1 2 P 2 S 5 A R 6 1 2 3 4 3 2 3 A 1 R 1 R 2 R 3 R 4 R 5 5 R 10 R 8 R 7 R 9 6 R 11 R 12 1 2 3 4 1 2 3 4 1 2 3 1 3 2 1 3 3 3 4 S 4 1 2 A2 P 1 2 P 2 S 5 A R 6 1 2 3 4 3 2 3 A 1 R 1 R 2 R...

Page 17: ...85 15min 30 max SERIE 550EL 210 380 210 A A 420 800 210 210 QUESTO DOCUMENTO E DI PROPRIETA ARRIS PADOVA ITALY IL SUO CONTENUTO E RISERVATO E PROTETTO A TERMINE DI LEGGE CON DIVIETO DI DIVULGAZIONE AN...

Page 18: ...S PADOVA ITALY IL SUO CONTENUTO E RISERVATO E PROTETTO A TERMINE DI LEGGE CON DIVIETO DI DIVULGAZIONE ANCHE PARZIALE A TERZI SENZA ESPLICITA AUTORIZZAZIONE SCRITTA SERIE 700EL GV407EL GV807EL 200 420...

Page 19: ...PADOVA ITALY IL SUO CONTENUTO E RISERVATO E PROTETTO A TERMINE DI LEGGE CON DIVIETO DI DIVULGAZIONE ANCHE PARZIALE A TERZI SENZA ESPLICITA AUTORIZZAZIONE SCRITTA SERIE 770EL GV 470EL GV 870EL 140 140...

Page 20: ...S PADOVA ITALY IL SUO CONTENUTO E RISERVATO E PROTETTO A TERMINE DI LEGGE CON DIVIETO DI DIVULGAZIONE ANCHE PARZIALE A TERZI SENZA ESPLICITA AUTORIZZAZIONE SCRITTA SERIE 710EL GV417EL GV817EL 80 125 8...

Page 21: ...PADOVA ITALY IL SUO CONTENUTO E RISERVATO E PROTETTO A TERMINE DI LEGGE CON DIVIETO DI DIVULGAZIONE ANCHE PARZIALE A TERZI SENZA ESPLICITA AUTORIZZAZIONE SCRITTA SERIE 900EL GV409EL GV809EL 200 420 8...

Page 22: ...ERMINE DI LEGGE CON DIVIETO DI DIVULGAZIONE ANCHE PARZIALE A TERZI SENZA ESPLICITA AUTORIZZAZIONE SCRITTA SERIE 910EL GV419EL GV819EL 80 125 80 400 400 200 420 800 200 90 120 210 90 120 380 210 660 90...

Page 23: ...In conformity with art 13 of Legislative Decree No 151 of 25 July 2005 Implementation of directives 2002 95 EC and 2003 108 EC regarding reduction of the use of hazardous substances in electrical and...

Page 24: ...35010 Cadoneghe PADOVA Italy Via G B Tiepolo 3B z i Tel 39 049 8874557 Fax 39 049 8874567 www arriscateringequipment it e mail arris arris c e it...

Reviews: