locking mechanism
locked
locking mechanism
unlocked
• With a 2 mm Allen key turn the locking mechanism
➪
photo
towards the “LOOSE” position until it stops.
• Turn the shutter angle adjusting mechanism
➪
photo
with
the same Allen key until the desired shutter angle is
reached.
• Turn the locking mechanism
➪
photo
towards the
“LOCK” position until this locks in place. The adjusting
mechanism may possibly have to be turned slightly back
and forth.
• By gently twisting the shutter angle adjusting mechanism,
check if the shutter angle has locked in correctly.
Operation of the camera when the mirror shutter
is not correctly locked in position may cause in-
correct exposure!
With an unlocked mirror shutter, the camera
may switch off during camera run!