should seal it. Leave the space between the edges of the board and the cover box open so the box 
can allow evaporation or drainage of any condensed moisture. 

Important,  Remove  Armature  keepers

  –  you  will  see  that  under  the  springs  of  each  relay  a 

small Z bent metal piece. This is an “armature keeper” it prevents the hinging part of the relay 
from  flying  off  the  hinges  during  shipping.    We  have  noticed  that  these  pieces  will  sometimes 
prevent  the  relays  from  closing  properly.    Please  remove  them  by  taking  the  spring  off  with  a 
small needle nose pliers, slip off the keeper, then put the spring back on.  

 

Armature  keepers  removal.  Spring  tension  is  adjusted  during  testing  before  shipping,  it 
requires experience to do it and normally should not be necessary for the user to adjust the 
tension.  

Tri-band beams or a multi-band antenna

 on a single feedline: Connect the wires of the bands 

to the SAME terminal of the SixPak relay matrix corresponding to the connector to  which that 
antenna  is  attached.  The  LED  will  light  showing  the  band  being  used  at  the  moment;  but  the 
second radio will not be able to use the multi-band antenna because the lockout will be in effect.  

Route all wires through the rubber grommets and holes in the boxes. 

Summary of Contents for SixPack

Page 1: ...nside or outside the shack Inside setup of the SixPak is accomplished by wiring two 6 wire cables rotor cable will work or just use two cables with a total of 13 conductors inside from the terminal st...

Page 2: ...em by taking the spring off with a small needle nose pliers slip off the keeper then put the spring back on Armature keepers removal Spring tension is adjusted during testing before shipping it requir...

Page 3: ...os are physically separated it is possible to connect two control boxes in parallel The LEDs would indicate to the two operators which bands were being used by the other operator To use in this manner...

Page 4: ...to avoid interference Teflon SO 239 or N connectors for reliability Extremely low insertion loss Will work up to 54 MHz Can be controlled from Automatic band decoders with 12 V DC outputs SixPak Contr...

Page 5: ...e and set up to the instructions in this link http www hamation com ControlCenter html Note The dual controllers are good to use with radios that are installed side by side and the operator s can reac...

Page 6: ...SixPak Manual rev 16 1 September 12 2016 Page 6 RatMaster just like the RatPak push button controller but with built in band decoder https www arraysolutions com ratmaster...

Page 7: ...port and measured at radio port SWR Radio to any Antenna port 1 1 1 1 1 15 1 Power Rating all modes CW SSB RTTY 5 kW 5 kW 3 kW This measurement is calculated not made Dimensions Relay Box 11 5 x 6 x...

Page 8: ...SixPak Manual rev 16 1 September 12 2016 Page 8 Relay Box Schematics...

Page 9: ...SixPak Manual rev 16 1 September 12 2016 Page 9 Dual Rotary Controller Schematics...