![ARRADA Farringdon 16 Operating & Installation Manual Download Page 29](http://html1.mh-extra.com/html/arrada/farringdon-16/farringdon-16_operating-and-installation-manual_2975609029.webp)
28
Arada Farringdon Stoves
OPERATING INSTRUCTIONS
Catalyst
The Arada Farringdon 16kw stove is fitted with a ceramic
catalyst to aid clean burning.
The catalyst should be inspected for damage annually and
if necessary replaced. The catalyst part number can be
found in the parts list on page 31.
Only replace with a genuine Arada Catalyst
Catalyst Bypass Control.
The control for the catalyst bypass is on the left and right
side of the stove in the position shown in Fig A.
Actuation is as shown on the label on the Left hand side.
The bypass should be placed in the open postion during
the lighting stage and prior to opening the door for
refueling.
The door/riddling tool is used to control the bypass by
insertion into the tri-lobed boss.
Always run the stove with the bypass door closed during
normal burning phase.
See Fig B for cutaway image of bypass actuation
Open Position (Cat bypassed)
Closed Position
Fig A
Fig B
Ceramic
Catalyst
Summary of Contents for Farringdon 16
Page 34: ...User Notes 34...