10
•
If supply cord is damaged, it must be replaced by an
authorized electrician to avoid hazard.
•
Attention: DO NOT use pans with diameter bigger than 18
cm because the cooker can overheat.
•
Do not operate your induction cooker on metal tables or metal
work-tops as the proximity to the induction power unit may
cause such metal surfaces to heat up thus causing possible
safety risk and also damage of the cooker.
Pan Detection
Pans with diameter smaller than 12 cm cannot be detected. During
pan detection, the indicator light flashes. If no pan or an unsuitable
pan is being used, then no power is transferred and the indicator
lamp flashes.
Trouble Shooting
Fault
Possible Cause
Action to take through
operator or operating
personnel
No heating
Indicator
operation is
OFF (dark)
•
No main supply
•
Check the electrical
supply (cable plugged in
the wall socket), check
preliminary fuses
•
Pan too small
(bottom diameter
less than 12 cm)
•
Use a suitable pan
•
Pan is not placed
in the center of the
heating area (the
cooker can’t detect
the pan)
•
Move the pan to the
center of the heating
area
•
Unsuitable pan
•
Choose a pan which is
recommended for
induction cooker
11
•
Cooker defective
•
Unplug the cooker from
the electrical supply
•
Ask your supplier for
repair service
Poor heating
Indicator
operation is
ON (shines)
•
Ambient
temperature is too
high (the cooling
system is not able
to keep the cooker
in normal
operating
conditions
2
)
•
Verify, that no hot air is
sucked in by the fan
•
Reduce the ambient
temperature
•
The air inlet temperature
must be lower than 40°C
•
One phase is
missing (only with
three phase
supply)
•
Check preliminary fuses
•
Cooker defective
•
Unplug the cooker from
the electrical supply
•
Ask your supplier for
repair service
Heating cycle
switches off
and on within
minutes
Fan is active
•
Air inlet or outlet
obstructed
•
Remove objects from air
inlet and air outlet slots
Heating
switches off
and on within
minutes
Fan is never
active
•
Fan detective
•
Fan control
defective
•
Ask your supplier for
repair service