ARO PD30*-*-B series Operator'S Manual Download Page 2

PD30XĆXĆB

PAGE  2 OF 8

OPERATING AND SAFETY PRECAUTIONS

READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE.

EXCESSIVE AIR PRESSURE

STATIC SPARK

HAZARDOUS MATERIALS

HAZARDOUS PRESSURE

 WARNING

 

EXCESSIVE AIR PRESSURE. Can cause personĆ

al injury, pump damage or property damage.

S

Do not exceed the maximum inlet air pressure as stated on the

pump model plate.

S

Be sure material hoses and other components are able to withĆ

stand fluid pressures developed by this pump. Check all

hoses for damage or wear. Be certain dispensing device is

clean and in proper working condition.

 WARNING

 

STATIC SPARK. Can cause explosion resulting

in severe injury or death. Ground pump and pumping system.

S

Use the pump grounding screw terminal provided. Use Aro

Part No. 66885Ć1 Ground Kit or connect a suitable ground wire

(12 ga. min.) to a good earth ground source.

S

Secure pump, connections and all contact points to avoid

vibration and generation of contact or static spark.

S

Consult local building codes and electrical codes for specific

grounding requirements.

S

After grounding, periodically verify continuity of electrical

path to ground. Test with an ohmmeter from each component

(e.g., hoses, pump, clamps, container, spray gun, etc.) to

ground to insure continuity. Ohmmeter should show 100

ohms or less.

S

Submerse the outlet hose end, dispensing valve or device in

the material being dispensed if possible. (Avoid free streamĆ

ing of material being dispensed.)

S

Use hoses incorporating a static wire.

S

Use proper ventilation.

S

Keep inflammables away from heat, open flames and sparks.

S

Keep containers closed when not in use.

 WARNING

 

Pump exhaust may contain contaminants. Can

cause severe injury. Pipe exhaust away from work area and

personnel.

S

In the event of a diaphragm rupture material can be forced out

of the air exhaust muffler.

S

Pipe the exhaust to a safe remote location when pumping hazĆ

ardous or inflammable materials.

S

Use a grounded 1" min. i.d. hose between the pump and the

muffler.

 WARNING

 

HAZARDOUS PRESSURE. Can result in serious

injury or property damage. Do not service or clean pump,

hoses or dispensing valve while the system is pressurized.

S

Disconnect air supply line and relieve pressure from the sysĆ

tem by opening dispensing valve or device and / or carefully

and slowly loosening and removing outlet hose or piping from

pump.

 WARNING

 

HAZARDOUS MATERIALS. Can cause serious

injury or property damage. Do not attempt to return a pump to

the factory or service center that contains hazardous material.

Safe handling practices must comply with local and national

laws and safety code requirements.

S

Obtain Material Safety Data Sheets on all materials from the

supplier for proper handling instructions.

 WARNING

 

EXPLOSION HAZARD. Models containing aluĆ

minum wetted parts cannot be used with III.ĆTrichloroethane,

Methylene Chloride or other Halogenated Hydrocarbon solĆ

vents which may react and explode.

S

Check pump motor section, fluid caps, manifolds and all

wetted parts to assure compatibility before using with solĆ

vents of this type.

 WARNING

 

MISAPPLICATION HAZARD. Do not use models

containing aluminum wetted parts with food products for huĆ

man consumption. Plated parts can contain trace amounts of

lead.

CAUTION

 

Verify the chemical compatibility of the pump

wetted parts and the substance being pumped, flushed or reĆ

circulated. Chemical compatibility may change with temperaĆ

ture and concentration of the chemical(s) within the

substances being pumped, flushed or circulated. For specific

fluid compatibility, consult the chemical manufacturer.

CAUTION

 

Maximum temperatures are based on mechaniĆ

cal stress only. Certain chemicals will significantly reduce

maximum safe operating temperature. Consult the chemical

manufacturer for chemical compatibility and temperature limĆ

its. Refer to PUMP DATA on page 1 of this manual.

CAUTION

 

Be certain all operators of this equipment have

been trained for safe working practices, understand it's limitaĆ

tions, and wear safety goggles / equipment when required.

CAUTION

 

Do not use the pump for the structural support of

the piping system. Be certain the system components are

properly supported to prevent stress on the pump parts.

S

Suction and discharge connections should be flexible conĆ

nections (such as hose), not rigid piped, and should be comĆ

patible with the substance being pumped.

CAUTION

 

Prevent unnecessary damage to the pump. Do

not allow pump to operate when out of material for long periĆ

ods of time.

S

Disconnect air line from pump when system sits idle for long

periods of time.

CAUTION

 

Use only genuine ARO replacement parts to asĆ

sure compatible pressure rating and longest service life.

 WARNING

CAUTION

 NOTICE

= Hazards or unsafe practices which could

result in severe personal injury, death or

substantial property damage.

= Hazards or unsafe practices which could

result in minor personal injury, product or

property damage.

= Important installation, operation or

maintenance information.

Summary of Contents for PD30*-*-B series

Page 1: ...pressure levels published here have been updated to an Equivalent Continuous Sound Level LAeq to meet the intent of ANSI S1 13Ć1971 CAGIĆPNEUĆ ROP S5 1 using four microphone locations NOTICE AllpossibleoptionsareshowninthecharthowevercertaincomĆ binationsmaynotberecommended consultarepresentativeorthefactoĆ ry if you have questions concerning availability GENERAL DESCRIPTION The ARO Diaphragm Pump...

Page 2: ...cause serious injury or property damage Do not attempt to return a pump to the factory or service center that contains hazardous material Safe handling practices must comply with local and national laws and safety code requirements S Obtain Material Safety Data Sheets on all materials from the supplier for proper handling instructions WARNING EXPLOSION HAZARD Models containing aluĆ minum wetted pa...

Page 3: ...E CONT D S Provide a clean work surface to protect sensitive internal moving parts from contamination from dirt and foreign matter during serĆ vice disassembly and reassembly S Keep good records of service activity and include pump in prevenĆ tive maintenance program S Before disassembling empty captured material in the outlet manĆ ifold by turning the pump upside down to drain material from the p...

Page 4: ...d 2 Y325Ć117 d B Y325Ć118 f B MANIFOLD THREAD FLUID CAP MATERIAL OPTIONS PD30XĆXXXĆ PD30XĆXAXĆ PD30XĆXCXĆ PD30XĆXHXĆ PD30XĆXSXĆ ITEM DESCRIPTION Size in inches QTY PART NO MTL PART NO MTL PART NO MTL PART NO MTL 6 Fluid Side Washer 2 94802 A 94803 SS 94947 Ha 94803 SS 9 Washer 3 16 i d x 2 o d x 5 32 2 Y13Ć12ĆT SS Y13Ć12ĆT SS 94949 Ha Y13Ć12ĆT SS 14 Cap Screw 3 4 Ć 16 x 3Ć1 4 2 Y5Ć134ĆT SS Y5Ć134Ć...

Page 5: ...ACK RED S PVDF N A N A SANTOPRENE TAN TAN SANTOPRENE GREEN N A BACKUP TEFLON WHITE WHITE VITON YELLOW Ć YELLOW S Ć STRIPE S DOT SANTOPRENE 43 22 68 32 61 7 8 7 5 144 k 21 22 21 180 175 k 70 k 69 60 FIGURE 1 6 TEFLON VIEWOF TWO PIECE TEFLON DIAPHRAGM 27 G Z Lubriplate FMLĆ2 is a white food grade petroleum grease MSDS available upon request D006 k Apply Lubriplate FMLĆ2 Grease to all O rings U Cups ...

Page 6: ...R SECTION SERVICE Service is divided into two parts 1 Pilot Valve 2 Major Valve GENERALREASSEMBLY NOTES S Air Motor Section Service is continued from Fluid Section repair S Inspect and replace old parts with new parts asnecessary Look for deep scratches on metallic surfaces and nicks or cuts in O rings S Take precautions to prevent cutting O rings upon installation S Lubricate O rings with Lubripl...

Page 7: ...ss section detail figure 3 above IMPORTANT BE CERTAIN TO ORIENT 115 SPACER LEGS AWAY FROM BLOCKING INTERNAL PORTS WHEN REASSEMBLING AIR SECTION 174 k 121 173 k 118 168 k 171 k 170 172 k 173 k 166 u k 167 136 110 k 177 114 k 132 k 176 174 k 103 181 PD30SĆ only 135 134 107 112 113 k 114 k 115 116 u Substitute these O rings for 166 on models PD30S FIGURE 2 101 114 k 114 k 113 k Optional 94117 Muffler...

Page 8: ...ion hose must be a nonĆcolĆ lapsing type capable of pulling a high vacuum S Check all joints on the inlet manifolds and suction connections These must be air tight S Inspect the pump for solid objects logged in the diaphragm chamĆ ber or the seat area DIMENSIONAL DATA Dimensions shown are for reference only they are displayed in inches and millimeters mm PD30XĆAXXĆXXXĆB 3 Ć 8 N P T F Ć 1 PD30XĆBXX...

Reviews: