ACM-IP2.1
ANALOGUE SUBSYSTEMS MODULE
User Manual
armtel.com
стр.
7/32
© Armtel
ENG
Table
1
– Main specification (end)
Parameter
Value
Maximum output current per one control line
4)
(for nominal power
voltage of 48 V), min, mA
40
1)
DC power supply voltage.
2)
Takin no account of power consumption of load connected to the control line.
3)
Only for direct calls without using sound files (except for local sound files with sampling
rate of 32 kHz (in the local memory) under SIP protocol and when using SIP-
codec G.722.1С.
When using Armtel-IP protocol, the bandwidth is 300 to 6800 kHz.
4)
Maximum permitted total output current of control lines when supplied from PoE Class 0
source (injector), max.,
А
: 0.22.
Note
— Parameter values are given with no account of error of measuring devices
1.3 Operating conditions
Climatic category of
АСМ
-IP2.1 according to GOST 15150-69 and values of exposure
factors are given in Table 2.
Table 2 — Values of exposure factors
Climatic category
according to
GOST 15150-69*
Values of exposure factors
Operating
temperature
range, °C
Upper value of
ambient air
humidity, %
Ambient atmospheric
pressure, kPa
(mmHg)
NF4.1
from -5 to +55
80
(at +25 °C without
moisture
condensation)
84 to 106.7
(630 to 800)
* Taking into account the values of exposure factors
АСМ
-IP2.1 satisfies vibration resistance and vibration strength requirements in
operating conditions (refer to Table 2) when exposed to sinusoidal vibration ranging from 2
to 10 Hz with peak acceleration amplitude of 55 m/s
2
.
АСМ
-IP2.1 satisfies requirements for electromagnetic interference resistance according
to GOST 30804.6.2-2013 (IEC 61000-6-2:2005) with performance criteria not lower than B.
Electromagnetic interference from
АСМ
-IP2.1 does not exceed standards set by
GOST 30804.6.4-2013 (IEC 61000-6-4:2006).
Electrical class of
АСМ
-IP2.1 according to GOST IEC 61140-2012 is III.