Shut off the main water and electrical supply.
Observe all local plumbing and building codes.
The Rada MX1 is a type 1, electronic, electrically operated, independently
mounted valve. It is intended for surface mounting and is for connection to the
mains water supply.
Isolator / Check valve / Filter housing supplied is an integral component of the tap,
failing to install will invalidate the product’s warranty.
The Rada MX1 must only be supplied from the power adaptor provided.
The power adaptor must be connected to the fixed wiring of the electrical supply
via a switched 3A fused spur.
If the power adaptor supply cord is damaged the power adapter must be replaced
by a competent person.
Where chlorine disinfection is practised, DO NOT exceed a chlorine concentration
of 50 mg/l (ppm) in water, per one hour dwell time. Such procedures must
be conducted strictly in accordance with the information supplied with the
disinfectant and with all relevant Guidelines/Approved Codes of Practice.
The use of the word ‘failsafe’ to describe the function of any thermostatic mixing
valve is both incorrect and misleading. In keeping with every other mechanism it
cannot be considered as being functionally infallible.
Malfunction of thermostatic mixing valves can be detected by the use of proper
temperature checking and maintenance routines.
Certain types of system can result in the thermostatic mixing valve having
excessive ‘dead-legs’ of pipework. Such systems can disguise the onset of
thermostatic mixing valve malfunction.
Ultimately, the user must exercise due diligence to ensure that the delivery of
warm water is at a stable, safe temperature.
Make sure that the water delivery does not cause splashing or overflow.
Make sure that the Rada MX1 is installed by a competent installer.
The product commissioning, clock (date/time) and tap set up can only be done in
conjunction with the “RADA AP1” available from the Apple APP store. Time and
date setting is critical to ensure data reporting is correct.
Note: Clock settings are lost after a period of 24hrs without mains power
When power is restored clock settings return to factory default (1st
February 2000) and will need to be reset via the APP
Important Safety Information
General