7
Alternate Method of Installation
Chart 7-1.
Manifold Size
Manifold Steam
Pipe Adapter
A
B
Jacket Conn. Size
Connection Size
90
1
/
2
" NPT
1
/
2
" NPT
2
1
/
8
"
4
1
/
2
"
91
1
/
2
" NPT
1
/
2
" NPT
2
1
/
8
"
4
1
/
2
"
92/1200
3
/
4
" NPT
3
/
4
" NPT
2
1
/
8
"
8
3
/
4
"
93/1300
1
1
/
4
" NPT
1" NPT
2
3
/
8
"
8
3
/
4
"
94/1400
2" NPT
2" NPT
3
1
/
2
"
10"
Manifold Pipe Adaptor
Steam Inlet Connection
B
A
Steam Jacket Connection
Manifold
Figure 7-2. Connection size and dimensions of manifold with pipe adaptor
Trap
Outlet
Temperature
Switch
Inlet
Strainer
Dirt Pocket
Drip Leg
Manifold
Pipe Adaptor
Manifold
OR
Figure 7-1. Vertical Installation
Dimensions and pipe sizes are given in
Tables 8-1 and 8-2 on Page 8.