22
Maintenance continued…
Note: Older handset units will display (c)
SENSOR 2008
(or 2003) by default.
Failed program output message will be (i)
ERROR COMMUNICATION 3.
Latest handset can program all previous sensor versions 2013, 2008 & 2003.
a)
Hand unit ON
b)
Navigate to Menu
4 PARAMETER
c)
SENSOR 2013
(Enter)
d)
MENU 4.4 URINAL
(Enter)
e)
AUTO-RINSE FREQUENCY: OFF
ARROW UP (To required Delay time) (Enter). Recommended: 6 or 12 hours.
f)
AUTO-RINSE DURATION:
(15 sec default)
ARROW UP or DOWN (To required Run Time). Recommended: 60sec (max).
g)
Point towards Sensor (approximate distance 100mm)
h)
Press ENTER
i)
TRANSMISSION OK
- if successfully programmed;
ERROR COMMUNICATION 2
– if programming failed
j)
Press ESCAPE (X) to get
BACKUP FUNCTION
k)
With BACKUP FUNCTION, previous settings are ‘Remembered’
- just point at next Tap / Sensor and press ENTER to repeat.
l)
Hand unit turns itself off after 2 minutes of non-use.
A brief summary of how to navigate the programming unit is as follows:
10 CLEANING CHROME SURFACES
When cleaning chromed products use only a mild detergent, rinse & wipe dry with
a soft cloth. Ideally clean after each use to maintain appearance.
Never use abrasive, scouring powders or scrapers. Never use cleaning agents
containing alcohol, ammonia, hydrochloric acid, sulphuric acid, nitric acid,
phosphoric acid or organic solvents. Use of incorrect cleaning products / methods may result in chrome
damage which is not covered by the manufacturer’s guarantee.