background image

FITTING FLUSH PIPE ASSEMBLY

The flush pipe is to be cut down as 
indicated prior to assembly, 

(Fig. 3).

Place the coupling nut

, coupling washer

and ring on to the top end of the  flush

pipe. Insert flush pipe into the flush valve

and tighten the coupling nut and coupling

washer onto the flush valve. Fit the flush

pipe connector to the bottom end of the

pipe.

Reposition assembled cistern

onto 

the closet bowl and screw to wall with 

No. 12 woodscrews (not supplied). Swing

flush pipe to one side at this stage to aid

fitting.

flush

valve

coupling

nut

seal

flush pipe

connector

flush pipe

Fig. 3

120

Cut to length

as required

CISTERN SUPPORT BRACKETS

For installations where the cistern does 

not rest on the rear of the closet bowl, 

alternative cistern support brackets 

are required. These are positioned and 

fixed on the wall, 

(Fig. 4),

locating in 

the recesses at the back of the cistern.

Secure the cistern to the wall using No. 12

woodscrews (not supplied). The flush pipe

will need to be cut to suit the installation.

Fig. 4

A

104

top face

of bracket leg

SUITE

305
355

A

396
407

The closet bowls have a horizontal outlet which conforms to the dimensions of 
BS 5503. The cistern is designed to suit current Water Regulations.

WARNING

Do not bed closet bowl to the floor with cement mortar otherwise the closet foot  could
split after installation.

SERVICING VALVES

The Water Regulations have a requirement to fit a servicing valve adjacent to the cistern.
This is to enable the water supply to be shut off, if required without shutting off the 
supply to other appliances.

CLOSET SEAT

It is recommended that fitting the closet seat be the last operation. This will avoid the risk
of scratching the seat when tiling etc.

ALL JOINTS

needing to be watertight are supplied with rubber gaskets.

Waterproof sealant 

MUST NOT BE USED

to seal, as this will have a detrimental effect on

all submerged rubber seals.

INSTALLATION

Position closet bowl (Fig. 2)

and mark

the outline of the closet bowl on the floor. 

Lower the empty cistern onto the rear of

the bowl, keeping cistern against the

wall(s). Mark the cistern fixing screw hole 

positions on the wall. Remove cistern and

closet bowl, drill and plug wall for cistern

fixings.

Fig. 2

A

SUITE

305
355

A

140
142

TECHNICAL INFORMATION

180

683

51

355

152

142

536

316

fixing screws

fixing screws

121

55

201

670

360

250

fixing centres

201

385

745

436

104

support brackets

55

121

201

639

315

250

fixing centres

180

outlet

102 OD

outlet

102 OD

673

426

305

150

140

530

314

fixing screws

fixing screws

51

187

385

735

104

support brackets

All dimensions shown in millimetres. Dimensions shown may vary within permitted tolerances

.

Fig. 1

4629 Schools cc wc instruction:4154 space cc wc suites.qxd  01/03/2008  16:11  Page 3